Candle KLVHSKONCT GC32-9172-00 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Candle KLVHSKONCT GC32-9172-00. Candle KLVHSKONCT GC32-9172-00 User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 522
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Candle Products Messages Manual
Volume 3
(KLVHS–KONCT)
GC32-9172-00
February 2004
Candle Corporation
100 North Sepulveda Blvd.
El Segundo, California 90245-9796
Przeglądanie stron 0
1 2 3 4 5 6 ... 521 522

Podsumowanie treści

Strona 1 - Volume 3

Candle Products Messages ManualVolume 3(KLVHS–KONCT)GC32-9172-00February 2004Candle Corporation100 North Sepulveda Blvd.El Segundo, California 90245-9

Strona 2

10 Candle Products Messages Manual (KLVHS–KONCT)KLVHS843 HANDLES IN POOL = handles, HANDLES IN USE = inuseExplanation: In addition to message KLVHS822

Strona 3 - Contents

100 Candle Products Messages Manual (KLVHS–KONCT)KLVST028 LOAD LIBRARY concat volser dsnameExplanation: These messages are logged at start-up time to

Strona 4

KLVSD001–KLXOP005 101KLVST035 INSTALLING ADDITIONAL ENTRYPOINT, |TRANSIENT |ALREADY RESIDENT |RELOCATION ERROR |BLDL ERROR [COMMAND=cmd |RESIDENT]Expl

Strona 5 - KLVHS001–KLVSC009

102 Candle Products Messages Manual (KLVHS–KONCT)KLVST040 WARNING: NO STORAGE FOR SOME LSR HIPERSPACE POOLSExplanation: A BLDVRP macro was issued to a

Strona 6

KLVSD001–KLXOP005 103 KLVTB001 TABLE DATABASE INITIAL LOAD COMPLETE: DSNAME(dsname)Explanation: During CT/Engine table initialization, the tables data

Strona 7 - KLVHS001–KLVSC009 7

104 Candle Products Messages Manual (KLVHS–KONCT)KLVTB006 NO LSR POOL ALLOCATEDExplanation: CT/Engine tables initialization was unable to process the

Strona 8

KLVSD001–KLXOP005 105KLVTB012 UNABLE TO LOAD TABLE CLUSTER: DSNAME(dsname) R15(value) RPLERRCD(value) DCR(hex)Explanation: CT/Engine tables initializa

Strona 9 - KLVHS001–KLVSC009 9

106 Candle Products Messages Manual (KLVHS–KONCT)User Response: If permanent table services are desired, allocate a tables database, create or update

Strona 10

KLVSD001–KLXOP005 107KLVTB021 TABLE CONVERTED: tableExplanation: The TDB CONVERT command has successfully converted table from Version 145 format to V

Strona 11 - KLVHS001–KLVSC009 11

108 Candle Products Messages Manual (KLVHS–KONCT)KLVTB027 INVALID KEY LENGTH IN TABLE DATABASE: SUPPLIED(actual) EXPECTED(valid)Explanation: The Versi

Strona 12

KLVSD001–KLXOP005 109KLVTB032 SORT ERROR: TABLE(table)Explanation: While processing a tables request, the CT/Engine tables manager detected invalid so

Strona 13 - KLVHS001–KLVSC009 13

KLVHS001–KLVSC009 11Message Type: INFO.KLVHS854 MAXIMUM STORAGE EVER IN USE = nnnnnExplanation: The maximum amount of storage in the storage pool that

Strona 14

110 Candle Products Messages Manual (KLVHS–KONCT)KLVTB036 RECOVERY FAILED: TABLE(table)Explanation: While processing a tables request, the CT/Engine t

Strona 15 - KLVHS001–KLVSC009 15

KLVSD001–KLXOP005 111KLVTB039 ROW-END ERROR: TABLE(table) READ(mmm) EXPECTED(nnn)Explanation: While processing a tables request, the CT/Engine tables

Strona 16

112 Candle Products Messages Manual (KLVHS–KONCT)KLVTB045 RESIDUAL RECORD DELETED: TABLE(table) SEQUENCE(nnn)Explanation: The CT/Engine tables manager

Strona 17

KLVSD001–KLXOP005 113KLVTB049 INVALID RLB CHAIN DETECTEDExplanation: The CT/Engine tables manager detected an error while attempting to lock a row fro

Strona 18

114 Candle Products Messages Manual (KLVHS–KONCT)KLVTI201 INVALID $STMX REQUEST DETECTEDExplanation: A CT/Engine timing service has been passed invali

Strona 19 - KLVHS001–KLVSC009 19

KLVSD001–KLXOP005 115KLVTR003 INVALID PREFIX CHARACTER: ‘arg’Explanation: The TRACE command contains an invalid prefix character arg as one of the par

Strona 20

116 Candle Products Messages Manual (KLVHS–KONCT)KLVTR022 TRACE REQUEST REJECTED. INVALID CLASS(class) SPECIFIEDExplanation: An invalid CLASS was spec

Strona 21 - KLVHS001–KLVSC009 21

KLVSD001–KLXOP005 117KLVTR029 class: statExplanation: This message displays the status of internal trace class class. stat is its status.System Action

Strona 22

118 Candle Products Messages Manual (KLVHS–KONCT)KLVVL001 VSAM SERVICES NOT AVAILABLE FOR VIEWLOGExplanation: VIEWLOG requires VSAM support, but the C

Strona 23 - KLVHS001–KLVSC009 23

KLVSD001–KLXOP005 119KLVVL007 SHOWCB FIELDS=RPLLEN ERROR: R15(r15) R0(r0)Explanation: A SHOWCB macro instruction issued to obtain the length of a VSAM

Strona 24

12 Candle Products Messages Manual (KLVHS–KONCT)Message Type: INFO.KLVIN000 CT/IX INTERFACE INITIALIZEDExplanation: The CT Posix environment has been

Strona 25 - KLVHS001–KLVSC009 25

120 Candle Products Messages Manual (KLVHS–KONCT)KLVVL012 DISP(value) IS INVALID; DEFAULTS TO OLDExplanation: An invalid value was coded on the DISP k

Strona 26

KLVSD001–KLXOP005 121KLVVL017 parametersExplanation: As the parameters in module KLVINVLG are read, a log audit trail is created.System Action: None.U

Strona 27 - KLVHS001–KLVSC009 27

122 Candle Products Messages Manual (KLVHS–KONCT)KLVVP013 "TAG" MAY ONLY BE SPECIFIED IN THE VM VERSION OF THE PRODUCTExplanation: "TAG

Strona 28

KLVSD001–KLXOP005 123KLVVP019 VPRINTER APPLICATION appl STARTED: PHYSPRT (printer)Explanation: Application appl with physical printer printer was succ

Strona 29 - KLVHS001–KLVSC009 29

124 Candle Products Messages Manual (KLVHS–KONCT)KLVVP031 ERROR RECONCILING CURRENT SESSION WITH VPRINTER REQUEST CHAIN. REQUEST=requestExplanation: A

Strona 30

KLVSD001–KLXOP005 125KLVVP036 SYSOUT OPEN FAILED FOR VPRINTER APPLICATION applExplanation: The VPRINTER application was unable to obtain a SYSOUT data

Strona 31 - KLVHS001–KLVSC009 31

126 Candle Products Messages Manual (KLVHS–KONCT)KLVVP201 VPO TERMINATEDExplanation: The VPO facility has terminated.System Action: The facility is no

Strona 32

KLVSD001–KLXOP005 127KLVVP305 PRINT REQUEST STATUS FLAGS:Explanation: A VPRINTQ command was issued. Session status messages follow this message.System

Strona 33 - KLVHS001–KLVSC009 33

128 Candle Products Messages Manual (KLVHS–KONCT)KLVVP311 TERM REQUEST REQUIRES A SPECIFIED VPRINTERExplanation: A VPRINTQ command was issued with the

Strona 34

KLVSD001–KLXOP005 129KLVVP400 VPRINTER: vprt -> CURRENT PHYSICAL PRINTER: phys_prtExplanation: A VPRINTD command was issued. vprt is the VPRINTER n

Strona 35 - KLVHS001–KLVSC009 35

KLVHS001–KLVSC009 13KLVIN406 STARTUP ERROR: MODULE(modname) R15(r15)Explanation: During CT/Engine start-up, module modname detected an error. r15 shou

Strona 36

130 Candle Products Messages Manual (KLVHS–KONCT)KLVVP406 RETRY IN PROGRESS: YES/NOExplanation: A VPRINTD command was issued. This message reports whe

Strona 37 - KLVHS001–KLVSC009 37

KLVSD001–KLXOP005 131KLVVP411 SESSION HONORS RELREQ: YES/NOExplanation: A VPRINTD command was issued. This message reports whether or not the VPRINTER

Strona 38

132 Candle Products Messages Manual (KLVHS–KONCT)KLVVP416 PHYSICAL SESSION TIMEOUT: mm:ssExplanation: A VPRINTD command was issued. This message repor

Strona 39 - KLVHS001–KLVSC009 39

KLVSD001–KLXOP005 133KLVVP422 LOGMODE OVERRIDE SPECIFIED: xxxxxxxxExplanation: A VPRINTD command was issued. This message reports the LOGMODE for the

Strona 40

134 Candle Products Messages Manual (KLVHS–KONCT)KLVVP427 SYSOUT FORM: formExplanation: A VPRINTD command was issued. This message reports the FORM of

Strona 41 - KLVHS001–KLVSC009 41

KLVSD001–KLXOP005 135KLVVS002 CLUSTER cid: BFRFND(bfrfnd) BUFRDS(bufrds) NUIW(nuiw) STRMAX(strmax) UIW(uiw)Explanation: This message is logged to crea

Strona 42

136 Candle Products Messages Manual (KLVHS–KONCT)KLVVS011 VSAM ACB GENERATION ERROR: R15(r15) R0(r0), TERMINATION SCHEDULEDExplanation: During CT/Engi

Strona 43 - KLVHS001–KLVSC009 43

KLVSD001–KLXOP005 137KLVVS016 VSAM ACB REQUIRES n BYTES, ONLY m BYTES WERE RESERVED, INCREASE &$CCBSP$Explanation: The amount of storage reserved

Strona 44

138 Candle Products Messages Manual (KLVHS–KONCT)KLVVS021 VSAM LOGIC ERROR: RPL(addr) CLUSTER(name) RPLFDBWD(rplfdbwd) RPLIDWD(rplidwd) RPLOPTCD(rplop

Strona 45 - KLVHS001–KLVSC009 45

KLVSD001–KLXOP005 139KLVVS041 FREEPCTWARN VALUE INVALID: pctExplanation: A FREEPCTWARN value is larger than 100 or less than 0.System Action: The rema

Strona 46

14 Candle Products Messages Manual (KLVHS–KONCT)KLVIN412 STARTUP MODULE module NOT FOUNDExplanation: An override statement references a start-up modul

Strona 47 - KLVHS001–KLVSC009 47

140 Candle Products Messages Manual (KLVHS–KONCT)KLVVS051 SHOWCB RC=rc REASON=rs dd dsn; SPACE MESSAGES DISABLEDExplanation: Space usage could not be

Strona 48

KLVSD001–KLXOP005 141KLVVT004 VTAM ACCESS METHOD SUPPORT VECTOR LIST RELEASE LEVEL level COMPONENT ID id FUNCTION LIST list VECTOR vectorExplanation:

Strona 49

142 Candle Products Messages Manual (KLVHS–KONCT)REQUEST RETRYThe request was rejected because of a storage shortage. CT/Engine will wait one second a

Strona 50

KLVSD001–KLXOP005 143If a data item cannot be located, it is omitted from the message. If DEBUG(Y) was specified in the CT/Engine KLVSYSIN file, the c

Strona 51 - KLVHS001–KLVSC009 51

144 Candle Products Messages Manual (KLVHS–KONCT)KLVVT021 VTAM LERAD EXITExplanation: A VTAM logic error was detected, causing the CT/Engine LERAD exi

Strona 52

KLVSD001–KLXOP005 145KLVVT031 LOGON REJECTED: LU(luname) CID(cid)Explanation: Either:1. a resource ID could not be assigned, or2. session initializati

Strona 53 - KLVHS001–KLVSC009 53

146 Candle Products Messages Manual (KLVHS–KONCT)KLVVT101 VTAM EXLST GENERATION ERROR: R15(r15) R0(r0) TERMINATION SCHEDULEDExplanation: An error was

Strona 54

KLVSD001–KLXOP005 147KLVVT106 VTAM RPL GENERATION ERROR: R15(r15) R0(r0) TERMINATION SCHEDULEDExplanation: An error was detected during the generation

Strona 55 - KLVHS001–KLVSC009 55

148 Candle Products Messages Manual (KLVHS–KONCT)KLVVT111 VTAM RPL REQUIRES n BYTES, ONLY m BYTES WERE RESERVED, INCREASE &$ARBSP$Explanation: The

Strona 56

KLVSD001–KLXOP005 149KLVVT251 SESSION SETUP ERROR: POOL(pool) APPLID(applid) PLU(plu) REQSTAT(rcfb)Explanation: There has been a failure to establish

Strona 57 - KLVHS001–KLVSC009 57

KLVHS001–KLVSC009 15User Response: Using the RC and service name, determine the cause of the error, correct it, and restart CT/Engine.Message Type: ER

Strona 58

150 Candle Products Messages Manual (KLVHS–KONCT)KLVVT506 VPO ACB GENERATION ERROR: R15(r15) R0(r0)Explanation: An error was detected upon execution o

Strona 59 - KLVHS001–KLVSC009 59

KLVSD001–KLXOP005 151KLVVT511 VPO INITIALIZATION COMPLETE: APPLID(applid)Explanation: VPO initialization has completed successfully.System Action: Non

Strona 60

152 Candle Products Messages Manual (KLVHS–KONCT)KLVVT902 INBOUND MESSAGE LIMIT EXCEEDED LU(luname) SESSION CANCELLEDExplanation: The limit of inbound

Strona 61 - KLVHS001–KLVSC009 61

KLVSD001–KLXOP005 153KLVVT953 parametersExplanation: As the parameters in module KLVINVSM are read, a log audit trail is created.System Action: None.U

Strona 62

154 Candle Products Messages Manual (KLVHS–KONCT)KLXIN001 subsys CONFIGURATION: <content of member>Explanation:System Action: The process contin

Strona 63 - KLVHS001–KLVSC009 63

KLVSD001–KLXOP005 155KLXIN003 TCP/IP INTERFACE INITIALIZEDExplanation: Initialization of the HPNS (TCP/IP) protocol stack has completed successfully.S

Strona 64

156 Candle Products Messages Manual (KLVHS–KONCT)User Response:Message Type: INFO.KLXIN006 TCP/IP INTERRUPT UNKNOWN: IPTYPE(iptype) IPPATHID(ippathid)

Strona 65 - KLVHS001–KLVSC009 65

KLVSD001–KLXOP005 157KLXOP000 <text in error>Explanation: The IPMVS operator command is in error. The syntax error is displayed in this message.

Strona 66

158 Candle Products Messages Manual (KLVHS–KONCT)KLXOP003 TCP/IP’,SUBCMD,’ FAILEDD: <failing subcommand>Explanation: The IPMVS operator subcomma

Strona 67

KM2EXPFF–KMCRCA002I 159KM2EXPFF–KMCRCA002IKM2EXPFF PROFILE EXPORT FAILEDExplanation: The profile export was unable to complete properly due to an erro

Strona 68

16 Candle Products Messages Manual (KLVHS–KONCT)KLVLR005 PURGE/CLEANUP EXIT ERROR DETECTED resnum1 - resname - resnum2Explanation: The CT/Engine logic

Strona 69

160 Candle Products Messages Manual (KLVHS–KONCT)KM2HDI99 CANSM2HD FAILED KM2HDI99 REASON (xxxx) SESSION (xxxxxxxx) HANDLE (xxxxxxxx)Explanation: The

Strona 70

KM2EXPFF–KMCRCA002I 161KM2IMPFF PROFILE IMPORT FAILEDExplanation: The profile import was unable to complete properly due to an error.System Action: Pr

Strona 71 - KLVHS001–KLVSC009 71

162 Candle Products Messages Manual (KLVHS–KONCT)KMC0005E Your request failed. MQSeries connection shutting down.Explanation: This reason code occurs

Strona 72

KM2EXPFF–KMCRCA002I 163KMC0016E Your request failed. MQSeries message too big for queue.Explanation: The Configuration Agent attempted to put a messag

Strona 73 - KLVHS001–KLVSC009 73

164 Candle Products Messages Manual (KLVHS–KONCT)KMC0022E Your request failed. MQSeries object damaged.Explanation: The object accessed by the Configu

Strona 74

KM2EXPFF–KMCRCA002I 165KMC0026E Your request failed. MQSeries queue is put inhibited.Explanation: The Configuration Agent attempted to get a message f

Strona 75 - KLVHS001–KLVSC009 75

166 Candle Products Messages Manual (KLVHS–KONCT)KMC0035E Your request failed. No space available for MQSeries queue.Explanation: The Configuration Ag

Strona 76

KM2EXPFF–KMCRCA002I 167KMC0041E Your request failed. Unexpected MQSeries error. The call was rejected because an unexpected error occurred.Explanation

Strona 77

168 Candle Products Messages Manual (KLVHS–KONCT)The queue name is resolved through a cell directory, and the remote Queue Manager name obtained from

Strona 78

KM2EXPFF–KMCRCA002I 169KMC0077E Your request failed. MQSeries maximum message length invalid.Explanation: The maximum message length specified for the

Strona 79 - KLVSD001–KLXOP005

KLVHS001–KLVSC009 17KLVLW003 LINES WRITTEN: linesExplanation: In response to the TLVLOG CT/Engine operator command, this message shows the number of l

Strona 80

170 Candle Products Messages Manual (KLVHS–KONCT)KMC0097E Your request failed. MQSeries object name not valid.Explanation: You attempted to create a n

Strona 81

KM2EXPFF–KMCRCA002I 171KMC0100E Your request failed. MQSeries channel configuration error.Explanation: A configuration error was detected in the chann

Strona 82

172 Candle Products Messages Manual (KLVHS–KONCT)KMC0108E Your request failed. Communication manager not available for MQSeries.Explanation: The MQSer

Strona 83

KM2EXPFF–KMCRCA002I 173KMC0117E Your request failed. MQSeries queue is not a transmission queue.Explanation: The queue specified in the channel defini

Strona 84

174 Candle Products Messages Manual (KLVHS–KONCT)KMC0123E Your request failed. MQSeries channel send exit name invalid.Explanation: The Send exit name

Strona 85

KM2EXPFF–KMCRCA002I 175KMC0126E Your request failed. MQSeries channel receive exit name invalid.Explanation: The Receive exit name specified for the c

Strona 86

176 Candle Products Messages Manual (KLVHS–KONCT)Note: If you are using any of the special characters in your connection name (for example, parenthese

Strona 87 - KLVSD001–KLXOP005 87

KM2EXPFF–KMCRCA002I 177KMC0137E Your request failed. MQSeries MQSET failed.Explanation: MQSeries MQSET call failed.User Response: Check whether the Qu

Strona 88

178 Candle Products Messages Manual (KLVHS–KONCT)KMC0148E Your request failed. MQSeries cluster queue cannot be a transmission queue.Explanation: The

Strona 89 - KLVSD001–KLXOP005 89

KM2EXPFF–KMCRCA002I 179KMC0155E This Queue Manager is not at the proper MQSeries version to support cluster participation.Explanation: You have attemp

Strona 90

18 Candle Products Messages Manual (KLVHS–KONCT)System Action: None.User Response: None.Severity: REPLY.KLVLW022 RKLVLOG IS NOW RECORDING ON ddnameExp

Strona 91 - KLVSD001–KLXOP005 91

180 Candle Products Messages Manual (KLVHS–KONCT)KMC0163E Your request to stop the Queue Manager failed.Explanation: You are attempting to stop a Queu

Strona 92

KM2EXPFF–KMCRCA002I 181KMC0169E The Configuration Agent was unable to open the MQSeries authorization file.Explanation: The Configuration Agent was un

Strona 93 - KLVSD001–KLXOP005 93

182 Candle Products Messages Manual (KLVHS–KONCT)KMC0175S An unexpected error occurred on a SETMQAUT command.Explanation: An internal MQSeries error o

Strona 94

KM2EXPFF–KMCRCA002I 183KMC0181E MQSeries storage classes are not supported on this platform.Explanation: You attempted to create a new MQSeries storag

Strona 95 - KLVSD001–KLXOP005 95

184 Candle Products Messages Manual (KLVHS–KONCT)KMC0187E Your request failed. The Configuration Agent was unable to open the MQSeries reply-to queue.

Strona 96

KM2EXPFF–KMCRCA002I 185KMC0191E Your request failed. The Configuration Agent could not establish communication with the remote MQSeries Queue Manager.

Strona 97 - KLVSD001–KLXOP005 97

186 Candle Products Messages Manual (KLVHS–KONCT)KMC0197E Cluster receiver channels not supported on this version of MQSeries.Explanation: You attempt

Strona 98

KM2EXPFF–KMCRCA002I 187KMC0201E The MQSeries object contains an invalid channel name @2.Explanation: The channel name that you specified for this obje

Strona 99 - KLVSD001–KLXOP005 99

188 Candle Products Messages Manual (KLVHS–KONCT)KMC0203E The MQSeries object contains an invalid namelist name @2.Explanation: The namelist name that

Strona 100

KM2EXPFF–KMCRCA002I 189KMC0205E The through Queue Manager field @1 is not defined in the configuration.Explanation: You have selected the ’Indirect co

Strona 101 - KLVSD001–KLXOP005 101

KLVHS001–KLVSC009 19KLVLW041 RKLVLOG DATASET DISABLED BY PERMANENT ERRORExplanation: A BSAM WRITE issued against the currently active RKLVLOG file fai

Strona 102

190 Candle Products Messages Manual (KLVHS–KONCT)If you are using any of the special characters in your connection name (for example, parentheses) you

Strona 103 - KLVSD001–KLXOP005 103

KM2EXPFF–KMCRCA002I 191KMC0208E The modename @2 associated with this object has an invalid length.Explanation: You specified an invalid modename for t

Strona 104

192 Candle Products Messages Manual (KLVHS–KONCT)KMC0216E The Environmental data @2 associated with this object has an invalid length.Explanation: You

Strona 105 - KLVSD001–KLXOP005 105

KM2EXPFF–KMCRCA002I 193KMC0222E The @1 application type is invalid.Explanation: You specified an invalid application type for the process.User Respons

Strona 106

194 Candle Products Messages Manual (KLVHS–KONCT)KMC0231E The default persistence type is invalid.Explanation: You specified an invalid default persis

Strona 107 - KLVSD001–KLXOP005 107

KM2EXPFF–KMCRCA002I 195KMC0237E The default transmit queue @1 is not defined as USAGE(XMITQ).Explanation: You defined a default transmit queue in the

Strona 108

196 Candle Products Messages Manual (KLVHS–KONCT)KMC0243E The transmit queue @1 associated with the channel is not defined as USAGE(XMITQ).Explanation

Strona 109 - KLVSD001–KLXOP005 109

KM2EXPFF–KMCRCA002I 197KMC0247E The remote queue @1 is not defined as USAGE(XMITQ) within the Queue Manager.Explanation: You defined a remote queue, b

Strona 110

198 Candle Products Messages Manual (KLVHS–KONCT)KMC0252E The heartbeat interval @1 is larger than disconnect interval @2.Explanation: You specified a

Strona 111 - KLVSD001–KLXOP005 111

KM2EXPFF–KMCRCA002I 199KMC0258W A Receiver/requester channel with the same name as this channel does not exist on the receiving Queue Manager @1.Expla

Strona 112

2 Candle Products Messages Manual (KLVHS–KONCT)Registered trademarks and service marks of Candle Corporation: AF/OPERATOR, AF/REMOTE, Availability Com

Strona 113 - KLVSD001–KLXOP005 113

20 Candle Products Messages Manual (KLVHS–KONCT)KLVNA001 SHOWCB FIELDS=(ACBLEN,RPLLEN) ERROR: R15(r15) R0(r0)Explanation: A VSAM SHOWCB was issued to

Strona 114

200 Candle Products Messages Manual (KLVHS–KONCT)KMC0263W The batch size associated with the channel is inconsistent with the receiver/requester chann

Strona 115 - KLVSD001–KLXOP005 115

KM2EXPFF–KMCRCA002I 201KMC0271E Invalid data conversion.Explanation: You specified an invalid convert property for the channel.User Response: Specify

Strona 116

202 Candle Products Messages Manual (KLVHS–KONCT)KMC0279E Invalid MVS value.Explanation: You specified an invalid MVS property for the Queue Manager.U

Strona 117 - KLVSD001–KLXOP005 117

KM2EXPFF–KMCRCA002I 203KMC0288E Invalid disconnect interval @2.Explanation: You specified an invalid disconnect interval for the channel.User Response

Strona 118

204 Candle Products Messages Manual (KLVHS–KONCT)KMC0297E Invalid long retry value @2.Explanation: You specified an invalid long retry count for the c

Strona 119 - KLVSD001–KLXOP005 119

KM2EXPFF–KMCRCA002I 205KMC0306E Invalid trigger message priority @2.Explanation: You specified an invalid trigger message priority for the queue.User

Strona 120

206 Candle Products Messages Manual (KLVHS–KONCT)KMC0314E Invalid Queue Manager autoconnect protocol @2.Explanation: You specified an invalid autoconn

Strona 121 - KLVSD001–KLXOP005 121

KM2EXPFF–KMCRCA002I 207KMC0320E Invalid page set id @2.Explanation: You specified an invalid page set id for the storage class.User Response: Specify

Strona 122

208 Candle Products Messages Manual (KLVHS–KONCT)KMC0326E Queue manager Log type invalid.Explanation: You specified an invalid logging type property f

Strona 123 - KLVSD001–KLXOP005 123

KM2EXPFF–KMCRCA002I 209KMC0334E Invalid volume @2 for Tandem NSK.Explanation: You specified an invalid volume for the Queue Manager.User Response: Spe

Strona 124

KLVHS001–KLVSC009 21KLVNA006 DATABASE INITIAL LOAD COMPLETE: DSNAME(dsname) CNTRLPT(cntrlpt)Explanation: Initialization has completed successfully for

Strona 125 - KLVSD001–KLXOP005 125

210 Candle Products Messages Manual (KLVHS–KONCT)KMC0341W The receiving Queue manager @1 is not a repository for the clusters associated with the send

Strona 126

KM2EXPFF–KMCRCA002I 211KMC0346E The referenced cluster namelist @1 is not found within the Queue Manager.Explanation: You defined a value for the Clus

Strona 127 - KLVSD001–KLXOP005 127

212 Candle Products Messages Manual (KLVHS–KONCT)KMC0350E Invalid maximum cluster workload data length @2.Explanation: You specified invalid cluster w

Strona 128

KM2EXPFF–KMCRCA002I 213KMC0355E Invalid pathname @2 for MQSecure exit.Explanation: You specified an invalid MQSecure LIB path for the channel.User Res

Strona 129 - KLVSD001–KLXOP005 129

214 Candle Products Messages Manual (KLVHS–KONCT)KMC0363E The managed cluster does not have at least one full repository Queue Manager.Explanation: Yo

Strona 130

KM2EXPFF–KMCRCA002I 215KMC0369E Client connection channels are not allowed on this platform.Explanation: You attempted to create an actual MQSeries cl

Strona 131 - KLVSD001–KLXOP005 131

216 Candle Products Messages Manual (KLVHS–KONCT)KMC0374E Invalid channel name: %s.Explanation: The channel name @2 that you specified for this object

Strona 132

KM2EXPFF–KMCRCA002I 217KMC0380E Invalid retention interval: %s.Explanation: You specified an invalid retention interval for the queue.User Response: S

Strona 133 - KLVSD001–KLXOP005 133

218 Candle Products Messages Manual (KLVHS–KONCT)KMC0383E Invalid Queue Manager alias name: %s.Explanation: You have selected the ’Indirect connection

Strona 134

KM2EXPFF–KMCRCA002I 219KMC0386E Invalid Queue Manager name: %s.Explanation: You specified an invalid Queue Manager name.User Response: Correct the Que

Strona 135

22 Candle Products Messages Manual (KLVHS–KONCT)Message Type: WARNING.KLVNA012 GENCB BLK=ACB ERROR: R15(r15) R0(r0)Explanation: A VSAM GENCB that was

Strona 136

220 Candle Products Messages Manual (KLVHS–KONCT)KMC0391E Invalid namelist name: %s.Explanation: The namelist name that you specified for this object

Strona 137 - KLVSD001–KLXOP005 137

KM2EXPFF–KMCRCA002I 221KMC0393E Invalid process name: %s.Explanation: The process name that you specified for this object is not a valid MQSeries proc

Strona 138

222 Candle Products Messages Manual (KLVHS–KONCT)KMC0400E Invalid short retry interval: %s.Explanation: The short interval specified for the channel i

Strona 139 - KLVSD001–KLXOP005 139

KM2EXPFF–KMCRCA002I 223KMC0408E Invalid Storage Class name %s.Explanation: You specified an invalid name for the storage class.User Response: Specify

Strona 140

224 Candle Products Messages Manual (KLVHS–KONCT)KMC0415E MCATYPE(THREAD) not allowed on this platform.Explanation: You have specified a Message Chann

Strona 141

KM2EXPFF–KMCRCA002I 225KMC0422E Invalid Default INI file %s.Explanation: You specified an invalid default ini file for the Queue Manager.User Response

Strona 142

226 Candle Products Messages Manual (KLVHS–KONCT)KMC0429E Invalid cluster name %s.Explanation: The cluster name associated with this object is not a v

Strona 143

KM2EXPFF–KMCRCA002I 227KMC0434I Message Encryption requires Connection Authentication, however Connection Authentication can be enabled independently

Strona 144

228 Candle Products Messages Manual (KLVHS–KONCT)KMC0440E Your request failed. The MQSeries Monitoring agent @1 returned an unknown code @2.Explanatio

Strona 145 - KLVSD001–KLXOP005 145

KM2EXPFF–KMCRCA002I 229KMC0447E Invalid application type: %s.Explanation: You entered an invalid application type for the process.User Response: Enter

Strona 146

KLVHS001–KLVSC009 23KLVNA017 DATABASE KEY LENGTH NOT n: DSNAME(dsname) CNTRLPT(cntrlpt)Explanation: While processing the NAM database dsname for contr

Strona 147 - KLVSD001–KLXOP005 147

230 Candle Products Messages Manual (KLVHS–KONCT)KMC0453E This QSGDISP value is not supported on this version of MQSeries.Explanation: You specified a

Strona 148

KM2EXPFF–KMCRCA002I 231KMC0459E Your request failed. Unknown MQSeries object name.Explanation: The actual object does not exist.User Response: Specify

Strona 149

232 Candle Products Messages Manual (KLVHS–KONCT)KMC0467S The authorization specification provided to the SETMQAUT command contained one or more items

Strona 150

KMQxx001E–KOCJ0046 233KMQxx001E–KOCJ0046KMQxx001E PARAMETER ERROR ON DOMAIN CALL. THE GATE BEING CALLED WAS call. THE PARAMETER IN ERROR WAS xx.Explan

Strona 151 - KLVSD001–KLXOP005 151

234 Candle Products Messages Manual (KLVHS–KONCT)KMQxx005E COMPONENT TRACE FAILED TO INITIALIZE FOR THE component COMPONENTExplanation: This is a gene

Strona 152

KMQxx001E–KOCJ0046 235KMQCI107E INVALID MINOR COMMANDExplanation: The minor verb on the KMQCMD command is invalid.System Action: The command is not ex

Strona 153 - KLVSD001–KLXOP005 153

236 Candle Products Messages Manual (KLVHS–KONCT)KMQCI114E UNABLE TO LOAD DOMAIN INITIALIZATION MODULEExplanation: CCC for MQSeries module KMQACIVC co

Strona 154

KMQxx001E–KOCJ0046 237KMQCI122E SAMPLE INTERVAL TIME MISSINGExplanation: A KMQCMD PERFORM STARTMON command was entered, but the sample interval time a

Strona 155

238 Candle Products Messages Manual (KLVHS–KONCT)KMQCI128E NAME OR SUBSYS PARAMETER REQUIREDExplanation: A SET MANAGER command was entered without the

Strona 156

KMQxx001E–KOCJ0046 239KMQCI134E DUPLICATE MANAGER FOR STATUS(ADD)Explanation: A SET MANAGER command specifies the STATUS(ADD) parameter, but a prior S

Strona 157 - KLVSD001–KLXOP005 157

24 Candle Products Messages Manual (KLVHS–KONCT)KLVNA021 DATABASE CONTROL RECORD UPDATE FAILED: DSNAME(dsn) CNTRLPT(cntrlpt)Explanation: During NAM in

Strona 158

240 Candle Products Messages Manual (KLVHS–KONCT)KMQCI139E DUPLICATE QUEUEExplanation: A SET QUEUE command with the STATUS(ADD) parameter was entered,

Strona 159 - KM2EXPFF–KMCRCA002I

KMQxx001E–KOCJ0046 241KMQCI146E TRACE HEAD NODE INITIALIZATION FAILED. RC=rc RSN=rsExplanation: CCC for MQSeries failed to define a trace to MVS/ESA c

Strona 160

242 Candle Products Messages Manual (KLVHS–KONCT)KMQCI150E RMANAGER NAME CANNOT BE GENERICExplanation: A KMQCMD SET RMANAGER command has been entered

Strona 161 - KM2EXPFF–KMCRCA002I 161

KMQxx001E–KOCJ0046 243KMQCI156E THE GROUP SPECIFIED IN THE EVENTQIN/OUT COMMAND DOES NOT EXIST. THE GROUP MUST BE DEFINED BEFORE THIS COMMAND IS ISSUE

Strona 162

244 Candle Products Messages Manual (KLVHS–KONCT)KMQCI303I MQ MANAGER (manager_name) IN SET(manager_name_mask) IS MONITOREDExplanation: This message i

Strona 163 - KM2EXPFF–KMCRCA002I 163

KMQxx001E–KOCJ0046 245KMQCI309I REMOTE MQ MANAGER mgr IS MONITORED VIA ROUTE LOCAL MANAGER mgrExplanation: The KMQCMD DISPLAY SETTINGS command is show

Strona 164

246 Candle Products Messages Manual (KLVHS–KONCT)6.SET MANAGER BLOCK IS NOT ACTIVE7.SET MANAGER BLOCK HAS AFFINITY TO A DIFFERENT SYSTEM8.MQSERIES VER

Strona 165 - KM2EXPFF–KMCRCA002I 165

KMQxx001E–KOCJ0046 247User Response: Depending on the reason, do one of the following:For reasons 1, 6, 7, issue the corrected SET RMANAGER command.Fo

Strona 166

248 Candle Products Messages Manual (KLVHS–KONCT)System Action: Options specified on this command are now in effect.User Response: None. This is an in

Strona 167 - KM2EXPFF–KMCRCA002I 167

KMQxx001E–KOCJ0046 249KMQCT129I ALL MESSAGES WITH GROUPID=groupID HAVE BEEN DELETED FROM QUEUE=queue IN QUEUE MANAGER=qmgrExplanation: All messages wi

Strona 168

KLVHS001–KLVSC009 25KLVNA034 DATABASE ALLOCATION FAILED - RESOURCE ERROR: DSNAME(dsname) CNTRLPT(cntrlpt)Explanation: CT/Engine was unable to allocate

Strona 169 - KM2EXPFF–KMCRCA002I 169

250 Candle Products Messages Manual (KLVHS–KONCT)KMQIT103E INITIALIZATION FUNCTION function FAILURE RESPONSE = rs REASON = rcExplanation: The named CC

Strona 170

KMQxx001E–KOCJ0046 251KMQMH102E MQIMONITOR(cms_address_space) UNABLE TO ESTABLISH ESTAE, RC=rcExplanation: MQI hook failed to establish recovery envir

Strona 171 - KM2EXPFF–KMCRCA002I 171

252 Candle Products Messages Manual (KLVHS–KONCT)KMQMI101E MQ API ERROR. OPERATION=op CC=cc RC=rcExplanation: An error occurred on an MQSeries API req

Strona 172

KMQxx001E–KOCJ0046 253KMQMI107I MONITORING STARTED FOR qmgr, ReplyToQ IS replyExplanation: The CCC for MQSeries Remote Monitoring Agent has been conta

Strona 173 - KM2EXPFF–KMCRCA002I 173

254 Candle Products Messages Manual (KLVHS–KONCT)KMQMI111I TERMINATE COMMAND PROCESSED. WAITING FOR SERVER INITIATION MESSAGE.Explanation: The CCC for

Strona 174

KMQxx001E–KOCJ0046 255KMQMI116E MQ MANAGER COMMAND SERVER NOT RESPONDING.Explanation: The CCC for MQSeries Remote Monitoring Agent attempted to verify

Strona 175 - KM2EXPFF–KMCRCA002I 175

256 Candle Products Messages Manual (KLVHS–KONCT)User Response: If you encounter problems with the Remote Monitoring Agent, verify that the CMS queue

Strona 176

KMQxx001E–KOCJ0046 257KMQMI130E SET GROUP SETTING option IS NOT SUPPORTEDExplanation: The specified SET GROUP option is not supported.System Action: P

Strona 177 - KM2EXPFF–KMCRCA002I 177

258 Candle Products Messages Manual (KLVHS–KONCT)KMQMI138E INVALID PERFORM STARTMON OPTION option reasonExplanation: The specified PERFORM STARTMON op

Strona 178

KMQxx001E–KOCJ0046 259KMQMI146E QUEUE queue EXISTS, STATUS=ADD IS INVALID. SET QUEUE IGNOREDExplanation: SET QUEUE with STATUS(ADD) refers to a queue

Strona 179 - KM2EXPFF–KMCRCA002I 179

26 Candle Products Messages Manual (KLVHS–KONCT)KLVNA101 UNABLE TO ACCESS NAM DATABASE: DSNAME(dsname) CNTRLPT(cntrlpt)Explanation: The network access

Strona 180

260 Candle Products Messages Manual (KLVHS–KONCT)User Response: Reset the manager in the SET QUEUE command and restart CCC for MQSeries.KMQMI153E SET

Strona 181 - KM2EXPFF–KMCRCA002I 181

KMQxx001E–KOCJ0046 261KMQMI158E NO MGRNAME OR GROUP DEFINED FOR resource. command IS IGNOREDExplanation: There is no group or no manager associated wi

Strona 182

262 Candle Products Messages Manual (KLVHS–KONCT)KMQMI166I NO SET MANAGER COMMAND IN THE COMMAND FILE. DEFAULT MANAGER IS MONITOREDExplanation: CCC fo

Strona 183 - KM2EXPFF–KMCRCA002I 183

KMQxx001E–KOCJ0046 263KMQMI168W NO QUEUE MANAGER WAS PROVIDED WITH -N COMMAND. DEFAULT MANAGER IS MONITOREDExplanation: This message is informational.

Strona 184

264 Candle Products Messages Manual (KLVHS–KONCT)KMQMI174I EVENT COMMUNICATION QUEUE ENDED WITH RETURN CODE rcExplanation: The return code rc was rece

Strona 185 - KM2EXPFF–KMCRCA002I 185

KMQxx001E–KOCJ0046 265KMQMI180E INVALID SET EVENTQIN/EVENTQOUT option reasonExplanation: The SET EVENTQIN or SET EVENTQOUT option is invalid for the r

Strona 186

266 Candle Products Messages Manual (KLVHS–KONCT)KMQMI185E ERROR IN WRITING TO filename. WRITE IS NOT SUCCESSFUL OR DATA LOSTExplanation: An error occ

Strona 187 - KM2EXPFF–KMCRCA002I 187

KMQxx001E–KOCJ0046 267KMQMI195E ERROR IN ISSUING _RROLLBCK COMMAND RC=rc ERRNO=errnoExplanation: The command_Rrollbck()has failed with return code rc

Strona 188

268 Candle Products Messages Manual (KLVHS–KONCT)KMQMI201W FAILED TO NOTIFY OFFLINE STATUSExplanation: This message appears if you terminate the agent

Strona 189 - KM2EXPFF–KMCRCA002I 189

KMQxx001E–KOCJ0046 269KMQMI207W SAMPINT IS INCREASED TO seconds SECONDS BECAUSE VALUE SPECIFIED IN CONFIGURATION FILE (seconds) IS TOO SMALL.Explanati

Strona 190

KLVHS001–KLVSC009 27System Action: This message is installation specific. The system action depends on the configuration of NAM. If using NAM to do th

Strona 191 - KM2EXPFF–KMCRCA002I 191

270 Candle Products Messages Manual (KLVHS–KONCT)2019 Hobj_Error 2087 Unknown_Remote_Q_Mgr2024 Syncpoint_Limit_Reached 2091 Xmit_Q_Type_Error2026 MD_E

Strona 192

KMQxx001E–KOCJ0046 271System Action: No rows are returned.User Response: Resolve the reason for the problem.KMQMQ101E ALESERV FAILED. REQ=request RC=r

Strona 193 - KM2EXPFF–KMCRCA002I 193

272 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ106E UNABLE TO WAIT FOR EVENT. RC=rcExplanation: CCC for MQSeries was unable to get events from

Strona 194

KMQxx001E–KOCJ0046 273KMQMQ113E COLLECTION TERMINATED FOR QMGR=sbid, REASON=reasonExplanation: Data collection has been terminated for a queue manager

Strona 195 - KM2EXPFF–KMCRCA002I 195

274 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ118E UNABLE TO OBTAIN COMMON STORAGE FOR SRB DRIVERExplanation: The CCC for MQSeries cross-memor

Strona 196

KMQxx001E–KOCJ0046 275KMQMQ124I CICS CHANNEL MONITORING ENDED FOR APPLID appl ON qmgrExplanation: CCC for MQSeries has stopped monitoring CICS channel

Strona 197 - KM2EXPFF–KMCRCA002I 197

276 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ143E MESSAGE WITH UNSUPPORTED CCSID=coded_character_set_id IS RECEIVED FROM QMGR=qmgrExplanation

Strona 198

KMQxx001E–KOCJ0046 277KMQMQ203E MQI component PROCESSOR INITIALIZATION FAILED. QMGR=queue_manager_name, RC=rcExplanation: Initialization of one of the

Strona 199 - KM2EXPFF–KMCRCA002I 199

278 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ210E MQI RECORD TYPE IS INVALID, QMGR=queue_manager_name, hexExplanation: The MQI data processor

Strona 200

KMQxx001E–KOCJ0046 279User Response: Contact Candle Customer Support.KMQMQ217E ERROR RETURNED BY $IPC ACCESS. RETURN CODE=rcExplanation: An unexpected

Strona 201 - KM2EXPFF–KMCRCA002I 201

28 Candle Products Messages Manual (KLVHS–KONCT)User Response: If you are a user viewing this message on your screen, supply a valid new password.Mess

Strona 202

280 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ223W MQI MONITORING FOR MGRNAME=mgrname LEFT 5K OF ECSA STORAGE IN ORDER TO MAINTAIN SYSTEM INTE

Strona 203 - KM2EXPFF–KMCRCA002I 203

KMQxx001E–KOCJ0046 281User Response: None.KMQMQ229E MQSERIES MESSAGE CORRUPTION FOR MESSAGE msgid. KEYWORD PREFIXES=(msgkwpfx|prstblkwpfx), QMGR=qmgrn

Strona 204

282 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ235W PERFORMANCE EVENTS DISABLED FOR QMGR xxxx. QUEUE STATISTICS INFORMATION CANNOT BE COLLECTE

Strona 205 - KM2EXPFF–KMCRCA002I 205

KMQxx001E–KOCJ0046 283System Action: Processing continues, but no data will be collected for the executing function.User Response: Ensure that the com

Strona 206

284 Candle Products Messages Manual (KLVHS–KONCT)System Action: The other agent is requested to release the monitoring function. When that is complet

Strona 207 - KM2EXPFF–KMCRCA002I 207

KMQxx001E–KOCJ0046 285System Action: The parameter is ignored.User Response: Ensure only valid, correctly formatted parameters are entered.KMQMQ407E a

Strona 208

286 Candle Products Messages Manual (KLVHS–KONCT)KMQMQ413I aaaaaaaa CCC for MQSeries stop acceptedExplanation: A successful request to terminate data

Strona 209 - KM2EXPFF–KMCRCA002I 209

KMQxx001E–KOCJ0046 287KMQTR103E BAD RETURN CODE FROM NAME/TOKEN SERVICESExplanation: CCC for MQSeries received a bad return code while attempting to u

Strona 210

288 Candle Products Messages Manual (KLVHS–KONCT)KMQTR112I TRACE STOPPING FOR COMP=component SUB=subExplanation: Application component tracing is bein

Strona 211 - KM2EXPFF–KMCRCA002I 211

KMQxx001E–KOCJ0046 289KMQVS101E DATASPACE CREATION FAILED. RC=rc REASON=rsExplanation: An error occurred while attempting to create the CCC for MQSeri

Strona 212

KLVHS001–KLVSC009 29KLVNA108 GROUP ACCESS REVOKED: CNTRLPT(cntrlpt) USERID(userid) [GROUP(group]) [TERM(terminal)] [APPL(appl)]Explanation: Security v

Strona 213 - KM2EXPFF–KMCRCA002I 213

290 Candle Products Messages Manual (KLVHS–KONCT)KMQW000W reason code-explanation textExplanation: An MQSeries error has occurred when performing the

Strona 214

KMQxx001E–KOCJ0046 291KMQW010E NOT ALLOWED BY COMMAND OPTIONExplanation: Agent does not allow executing the requested command. System Action: The com

Strona 215 - KM2EXPFF–KMCRCA002I 215

292 Candle Products Messages Manual (KLVHS–KONCT)KMQW018E NOT ALLOWED BY SECURITYExplanation: The requested command is not allowed by the security sy

Strona 216

KMQxx001E–KOCJ0046 293KMVCCC004E RULE FOR MANAGED OBJECT object IS TOO LONGExplanation: While creating or updating the Status Data Manager (SDM) resou

Strona 217 - KM2EXPFF–KMCRCA002I 217

294 Candle Products Messages Manual (KLVHS–KONCT)KMVCCC010E UNABLE TO INITIALIZE KMVCCC SERVICE QUEUEExplanation: An error occurred while setting up t

Strona 218

KMQxx001E–KOCJ0046 295KMVCCC016E UNABLE TO INITIALIZE SITUATION STATUS THREADExplanation: An error occurred while initializing the thread that monitor

Strona 219 - KM2EXPFF–KMCRCA002I 219

296 Candle Products Messages Manual (KLVHS–KONCT)KMVCCC024E ERROR return_code TRYING TO CREATE MESSAGE QUEUEExplanation: Return_code was received whil

Strona 220

KMQxx001E–KOCJ0046 297KMVCCC030E UNABLE TO CREATE DIALOG ENVIRONMENT FOR KMVCCC SERVICE THREADExplanation: An internal error occurred that will preven

Strona 221 - KM2EXPFF–KMCRCA002I 221

298 Candle Products Messages Manual (KLVHS–KONCT)KMVCCC037E UNABLE TO CREATE DIALOG ENVIRONMENT FOR SDM SERVICE THREADExplanation: An internal error o

Strona 222

KMQxx001E–KOCJ0046 299KMVCCC044E INVALID REQUEST request_code RECEIVED BY SDM SERVICEExplanation: The Status Data Manager (SDM) service received an in

Strona 223 - KM2EXPFF–KMCRCA002I 223

3Chapter 1. KLVHS001–KLVSC009 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Chapter 2. KLVSD001–KLXOP005 . . .

Strona 224

30 Candle Products Messages Manual (KLVHS–KONCT)KLVNA110 APPLICATION NOT AUTHORIZED: CNTRLPT(cntrlpt) USERID(userid) [GROUP(group]) [TERM(terminal)] [

Strona 225 - KM2EXPFF–KMCRCA002I 225

300 Candle Products Messages Manual (KLVHS–KONCT)KMVCCC051E ERROR return_code FROM SQL FETCH REQUESTExplanation: Return_code was received when fetchin

Strona 226

KMQxx001E–KOCJ0046 301KMVCCC058E UNABLE TO LOCATE EVENT FOR SITUATION situation_name ON NODE node_nameExplanation: No event entry could be found for t

Strona 227 - KM2EXPFF–KMCRCA002I 227

302 Candle Products Messages Manual (KLVHS–KONCT)User Response: Check the RKANDATV DD statement in the OMEGAVIEW started task JCL. Verify that the pro

Strona 228

KMQxx001E–KOCJ0046 303KMVCCC108I RKANDATV(member) tag=nnnExplanation: An attribute definition value was successfully parsed from the current input rec

Strona 229 - KM2EXPFF–KMCRCA002I 229

304 Candle Products Messages Manual (KLVHS–KONCT)KMVCCC118E ERROR return_code ADDING ROW TO TABLE tableExplanation: An error was encountered while add

Strona 230

KMQxx001E–KOCJ0046 305KMVCCC125E UNABLE TO ALLOCATE NODE STATUSExplanation: An error occurred while allocating storage for a node status object.System

Strona 231 - KM2EXPFF–KMCRCA002I 231

306 Candle Products Messages Manual (KLVHS–KONCT)KMVCCC131E ALLTYPE type NOT SUPPORTEDExplanation: An attempt to access a console from CCC/3270 has fa

Strona 232

KMQxx001E–KOCJ0046 307KMVCCC150E Error processing predicate: pdtExplanation: An error occurred processing the situation predicate.System Action: The u

Strona 233 - KMQxx001E–KOCJ0046

308 Candle Products Messages Manual (KLVHS–KONCT)System Action: NCP statistics information is not available.User Response: Log the information display

Strona 234

KMQxx001E–KOCJ0046 309KN3AF012 [TRACE DELETE] [TRACE DISPLAY] | [TRACE INSTALL] | [TRACE REMOVAL] | [TRACE START] | [TRACE STATUS] | [TRACE STOP] FAIL

Strona 235 - KMQxx001E–KOCJ0046 235

KLVHS001–KLVSC009 31KLVNA112 COMMAND NOT AUTHORIZED: CNTRLPT(cntrlpt) [OPERATOR(operator)] [COMMAND(command)] [TERM(terminal)] [APPL(appl)]Explanation

Strona 236

310 Candle Products Messages Manual (KLVHS–KONCT)KN3AF041 ETE CONNECTION FAILED — MODULE(error_module) RC(return_code) SC(sense_code)Explanation: Duri

Strona 237 - KMQxx001E–KOCJ0046 237

KMQxx001E–KOCJ0046 311Message Type: Internal error.KN3AF045 CAPTURE READER CODES — MODULE(error_module) RC(return_code) SC(sense_code)Explanation: Thi

Strona 238

312 Candle Products Messages Manual (KLVHS–KONCT)System Action: Cluster is loaded.User Response: None.Message Type: Information.KN3AF051 CLUSTER INITI

Strona 239 - KMQxx001E–KOCJ0046 239

KMQxx001E–KOCJ0046 313KN3AF056 ALLOCATING DATASET dsnameExplanation: VSAM cluster dsname is being allocated for OMEGAMON II for VTAM.System Action: VS

Strona 240

314 Candle Products Messages Manual (KLVHS–KONCT)KN3AF060 VSAM LOGGING DISABLED — MODULE(error_module) REASON (cccccccc)Explanation: VSAM logging is d

Strona 241 - KMQxx001E–KOCJ0046 241

KMQxx001E–KOCJ0046 315KN3AF110 dialog_function - UNABLE TO OBTAIN PASSED PARAMETER(parameter_name)Explanation: The dialog function module (dialog_func

Strona 242

316 Candle Products Messages Manual (KLVHS–KONCT)KN3AF115 KN3AFNM1 - UNABLE TO LOCATE SITE MONITOR TABLE: tablename.Explanation: The dialog function w

Strona 243 - KMQxx001E–KOCJ0046 243

KMQxx001E–KOCJ0046 317KN3AF120 NDM FUNCTIONS INITIALIZATION FAILED REASON(reason_code)Explanation: The automatic collection task (ACT) initialization

Strona 244

318 Candle Products Messages Manual (KLVHS–KONCT)KN3AF125 NCP DATA UPDATE ERRORS DETECTED RC(return_code) SC(sense code)Explanation: NCP data manager

Strona 245 - KMQxx001E–KOCJ0046 245

KMQxx001E–KOCJ0046 319KN3AF130 START REQUEST RESOURCE(resource_name) NPALU(npalu_name) GENDATE(generation_date) GENTIME(generation_time) FAILEDExplana

Strona 246

32 Candle Products Messages Manual (KLVHS–KONCT)KLVNA114 PASSTICKET REQUEST NOT AUTHORIZED: CNTRLPT(cntrlpt) [OPERATOR(operator)] [COMMAND(command)] [

Strona 247 - KMQxx001E–KOCJ0046 247

320 Candle Products Messages Manual (KLVHS–KONCT)KN3AF134 NCP TOPOLOGY NOT CREATED. WILL RETRY NEXT ACT CYCLE INTERVALExplanation: The NCP resources h

Strona 248

KMQxx001E–KOCJ0046 321KN3AF138 KN3AXNPB GET_HASH FUNCTION FAILED RC(return_code) MODULE(module_name)Explanation: An error was encountered in creating

Strona 249 - KMQxx001E–KOCJ0046 249

322 Candle Products Messages Manual (KLVHS–KONCT)KNOAF143 NCP VSAM LOGGING MODULE KN3AFNVW LOAD FAILED. NCP STATISTICS DATA NOT AVAILABLE.Explanation:

Strona 250

KMQxx001E–KOCJ0046 323KN3AF148 module_name LOWER LEVEL MONITORED RESOURCES EXIST FOR resource_nameExplanation: A request to stop monitoring an NCP res

Strona 251 - KMQxx001E–KOCJ0046 251

324 Candle Products Messages Manual (KLVHS–KONCT)KN3AF153 ACT NPB CHECK FOR RESOURCE(ncp_resource_name) NPALU(npalu_name) FAILED RC(return_code)Explan

Strona 252

KMQxx001E–KOCJ0046 325KN3AF157 TOPOLOGY UPATE FUNCTIONS MODULE KN3AFNUT LOAD FAILED. NCP STATISTICS DATA NOT AVAILABLE.Explanation: The Automatic Coll

Strona 253 - KMQxx001E–KOCJ0046 253

326 Candle Products Messages Manual (KLVHS–KONCT)KN3CT000 TCP/IP STATISTICS COLLECTOR INITIALIZATION COMPLETEExplanation: The TCP/IP collector success

Strona 254

KMQxx001E–KOCJ0046 327KN3CT009 {TCP/IP COLLECTOR | MIB BROWSER} MEMORY ALLOCATION FAILEDExplanation: A memory allocation failed in the specified funct

Strona 255 - KMQxx001E–KOCJ0046 255

328 Candle Products Messages Manual (KLVHS–KONCT)KN3CT015 SNMP MANAGER ATTACH FAILED: RC(return_code)Explanation: The attach of the SNMP manager task

Strona 256

KMQxx001E–KOCJ0046 329KN3CT102 {TCP/IP SERVICE THREAD | MIB BROWSER | XMCS} ABENDED, CODE=abend_code, PSW=program_status_word, ROUTINE=program_nameExp

Strona 257 - KMQxx001E–KOCJ0046 257

KLVHS001–KLVSC009 33KLVNA253 RESOURCE LIST BUILD DISABLED, NOT APF AUTHORIZEDExplanation: An attempt was made (either at initialization or through the

Strona 258

330 Candle Products Messages Manual (KLVHS–KONCT)KN3CT112 $GMEM FAILED FOR COMMAND OUTPUT RECORDExplanation: A memory allocation failed in the TCP/IP

Strona 259 - KMQxx001E–KOCJ0046 259

KMQxx001E–KOCJ0046 331KN3CT125 NAME=name STATUS=status HOST=host IPADDR=xxx.xxx.xxx.xxxExplanation: One KN3CT125 message per TCP/IP image follows mess

Strona 260

332 Candle Products Messages Manual (KLVHS–KONCT)KN3CT202 KN3CT202 module - STORAGE ALLOCATION FAILURE SIZE = bytesExplanation: The specified module w

Strona 261 - KMQxx001E–KOCJ0046 261

KMQxx001E–KOCJ0046 333KN3CT208 KN3CT208 KN3AITXB - EZASMI GETHOSTNAME FAILUREExplanation: Module KN3AITXB could not perform a GETHOSTBYNAME function v

Strona 262

334 Candle Products Messages Manual (KLVHS–KONCT)KN3CT303 KN3CT303 KN3AITDD - INVALID ELEMENT PARAMETER parmExplanation: Module KN3AITDD received a re

Strona 263 - KMQxx001E–KOCJ0046 263

KMQxx001E–KOCJ0046 335by an adjacent plus (+) sign. When the input field is not promptable, you must type the requested data.System Action: None.User

Strona 264

336 Candle Products Messages Manual (KLVHS–KONCT)KN3CV011 USER COMMANDS UPDATEDExplanation: The user added, changed or deleted a user VTAM command.Sys

Strona 265 - KMQxx001E–KOCJ0046 265

KMQxx001E–KOCJ0046 337KN3CV018 WRAP DETECTED IN SIO COUNTER; DATA REINITIALIZEDExplanation: A reset condition has been detected for a VTAM SIO counter

Strona 266

338 Candle Products Messages Manual (KLVHS–KONCT)KN3CV024 DIALOG ERRORExplanation: A user with administrator authority issued the DIALOG dlgname comma

Strona 267 - _Rrollbck()

KMQxx001E–KOCJ0046 339KN3CV030 SELECT THE “ACTIONS” PULL-DOWN MENUExplanation: One or more / selection characters have been entered, but no actions ha

Strona 268

34 Candle Products Messages Manual (KLVHS–KONCT)KLVNT002 "NTD dialog" DIALOG INVOCATION FAILED; DIALOG MANAGER RC(rc)Explanation: The non-te

Strona 269

340 Candle Products Messages Manual (KLVHS–KONCT)KN3CV037 GLOBAL OPTIONS UPDATEDExplanation: A user with administrator authority pressed Enter while v

Strona 270

KMQxx001E–KOCJ0046 341KN3CV043 ETE INTERFACE DISABLEDExplanation: The ETE response time monitor component is currently disabled. This is the initial d

Strona 271

342 Candle Products Messages Manual (KLVHS–KONCT)KN3CV047 THE SAS CLIST WAS NOT ENTERED IN THE CORRECT FORMAT. PLEASE USE THE FOLLOWING FORMAT: CANDLE

Strona 272

KMQxx001E–KOCJ0046 343KN3CV052 MONITORING STARTEDExplanation: The user requested monitoring of a subarea and/or VRs while working with the Virtual Rou

Strona 273 - KMQxx001E–KOCJ0046 273

344 Candle Products Messages Manual (KLVHS–KONCT)KN3CV058 MONITOR OPTIONS UPDATE ERRORExplanation: An internal error was detected while attempting to

Strona 274

KMQxx001E–KOCJ0046 345KN3CV065 SMF DEFINITION ADDEDExplanation: The user added a response time SMF definition.System Action: The SMF definition is add

Strona 275 - KMQxx001E–KOCJ0046 275

346 Candle Products Messages Manual (KLVHS–KONCT)KN3CV072 USER AUTHORITY CHANGEDExplanation: An administrator changed an existing user’s.s authorities

Strona 276

KMQxx001E–KOCJ0046 347KN3CV080 NAVIGATION NOT ALLOWEDExplanation: The user attempted to navigate to a panel that is already active in the stack. As na

Strona 277 - KMQxx001E–KOCJ0046 277

348 Candle Products Messages Manual (KLVHS–KONCT)KN3CV087 TRACE IS NOT ACTIVEExplanation: The user attempted to stop a trace that was never started.Sy

Strona 278

KMQxx001E–KOCJ0046 349KN3CV094 ALLOCATE FAILED FOR SYSOUT DATASETExplanation: An internal error was detected while closing the screen print log.System

Strona 279 - KMQxx001E–KOCJ0046 279

KLVHS001–KLVSC009 35KLVOP005 APPLICATION NOT ACCEPTING COMMANDS [text]Explanation: A command was issued and directed to a CT/Engine application that d

Strona 280

350 Candle Products Messages Manual (KLVHS–KONCT)KN3CV101 PRINTER OPTIONS UPDATEDExplanation: The user pressed Enter while viewing the Printer \Option

Strona 281 - KMQxx001E–KOCJ0046 281

KMQxx001E–KOCJ0046 351KN3CV107 ETE STARTED TASK IS NOT AVAILABLEExplanation: OMEGAMON II has detected that the ETE Response Time feature is currently

Strona 282

352 Candle Products Messages Manual (KLVHS–KONCT)KN3CV112 REQUESTED PIU WAS NOT FOUNDExplanation: A VTAM Trace browse request was issued. The requeste

Strona 283 - KMQxx001E–KOCJ0046 283

KMQxx001E–KOCJ0046 353KN3CV119 ENTER YES OR NOExplanation: This input field requires a value of Yes or No.System Action: None.User Response: Specify Y

Strona 284

354 Candle Products Messages Manual (KLVHS–KONCT)KN3CV125 THE CATEGORIES SELECTION IS ONLY VALID FOR THE IO00 BUFFER POOLExplanation: When accessing a

Strona 285 - KMQxx001E–KOCJ0046 285

KMQxx001E–KOCJ0046 355KN3CV130 VALID RANGE IS 128–255Explanation: The SMF record number to be generated must be in the range 128–255.System Action: No

Strona 286

356 Candle Products Messages Manual (KLVHS–KONCT)KN3CV136 VALID RANGE IS 10–3600Explanation: The automatic screen refresh interval must be in the rang

Strona 287 - KMQxx001E–KOCJ0046 287

KMQxx001E–KOCJ0046 357KN3CV142 UNABLE TO FIND THE ACTUAL RPL. THE CRPL IS DISPLAYED INSTEAD. MOST OF THE DATA FROM THE ORIGINAL RPL CAN BE FOUND IN TH

Strona 288

358 Candle Products Messages Manual (KLVHS–KONCT)KN3CV148 TRACE NOT STARTEDExplanation: The selected trace was not started.System Action: None.User Re

Strona 289 - KMQxx001E–KOCJ0046 289

KMQxx001E–KOCJ0046 359KN3CV154 SPECIFY EITHER RESOURCE NAME OR NETWORK ADDRESSExplanation: User entered both a resource name and a network address.Sys

Strona 290

36 Candle Products Messages Manual (KLVHS–KONCT)KLVOP012 *** ACTIVE RESOURCE LIST *** class.arg: USE(user) TOKEN(rsid) OWNER(owner) class.arg: USE(use

Strona 291 - KMQxx001E–KOCJ0046 291

360 Candle Products Messages Manual (KLVHS–KONCT)KN3CV160 STORAGE REQUIRED FOR MODELLING NOT AVAILABLE. ENSURE THAT LIMIT(23,X) IS CODED FOR THE START

Strona 292

KMQxx001E–KOCJ0046 361KN3CV166 ENTER P OR UExplanation: The only acceptable characters to specify in this field are P (PUs) and U (LUs).System Action:

Strona 293 - KMQxx001E–KOCJ0046 293

362 Candle Products Messages Manual (KLVHS–KONCT)KN3CV172 RESOURCE HAS NO SUBORDINATE RESOURCESExplanation: A List action was selected for a resource

Strona 294

KMQxx001E–KOCJ0046 363KN3CV178 NO EXCEPTIONS ARE GENERATED FOR THIS FIELDExplanation: Exceptions were requested for a data type that has no threshold

Strona 295 - KMQxx001E–KOCJ0046 295

364 Candle Products Messages Manual (KLVHS–KONCT)KN3CV184 RESOURCE MUST BE AN LU OR TERMINALExplanation: User has requested resource analysis for a re

Strona 296

KMQxx001E–KOCJ0046 365KN3CV189 GROUP DESCRIPTION ALREADY EXISTSExplanation: Group description is already assigned to a group being monitored by ETE.Sy

Strona 297 - KMQxx001E–KOCJ0046 297

366 Candle Products Messages Manual (KLVHS–KONCT)KN3CV198 THE TREND RECORDING INTERVAL (interval) IS LESS THAN THE NCP COLLECTION INTERVAL (interval).

Strona 298

KMQxx001E–KOCJ0046 367KN3CV207 INVALID SCROLL AMOUNTExplanation: While attempting to scroll forward, an invalid scroll amount was entered in the line

Strona 299 - KMQxx001E–KOCJ0046 299

368 Candle Products Messages Manual (KLVHS–KONCT)KN3CV214 UPDATE ERRORExplanation: An error occurred during an update operation.System Action: None.Us

Strona 300

KMQxx001E–KOCJ0046 369KN3CV221 AT LEAST ONE ENTRY IS REQUIREDExplanation: User pressed Enter is a data entry dialog that required an entry and no entr

Strona 301 - KMQxx001E–KOCJ0046 301

KLVHS001–KLVSC009 37KLVOP025 number SUBTASK(S) QUIESCED: DQA(addr)Explanation: This message is logged to create an audit trail of each active subtask

Strona 302

370 Candle Products Messages Manual (KLVHS–KONCT)KN3CV227 command COMMAND FAILEDExplanation: An attempt to execute the indicated command failed.System

Strona 303 - KMQxx001E–KOCJ0046 303

KMQxx001E–KOCJ0046 371KN3FC003 KN3AYFCV NOT AVAILABLE. INSTALL OPTION REQUIRED.Explanation: The KN3AYFCV resource was not found while processing one o

Strona 304

372 Candle Products Messages Manual (KLVHS–KONCT)KN3FC012 <status text>Explanation: This is a prefix for feature control command (KN3FCCMD) STAT

Strona 305 - KMQxx001E–KOCJ0046 305

KMQxx001E–KOCJ0046 373KN3FC023 <status text>Explanation: This is a prefix for feature control command (KN3FCCMD) STATUS SEVT output.System Actio

Strona 306

374 Candle Products Messages Manual (KLVHS–KONCT)KN3FC030 NCPC NPALU COLLECTOR INSTALLATION COMPLETEExplanation: The feature control command (KN3FCCMD

Strona 307 - KMQxx001E–KOCJ0046 307

KMQxx001E–KOCJ0046 375KN3FC045 <status text>Explanation: This is a prefix for feature control command (KN3FCCMD) STATUS NCPC output.System Actio

Strona 308

376 Candle Products Messages Manual (KLVHS–KONCT)KN3FC060 NDMT NCP DATA MANAGER TASK STOP FAILED ROUTINE=KN3AHNT2 REASON=reason_code RETURN=return_cod

Strona 309 - KMQxx001E–KOCJ0046 309

KMQxx001E–KOCJ0046 377KN3FC074 <status text>Explanation: This is a prefix for feature control command (KN3FCCMD) STATUS DBUG output.System Actio

Strona 310

378 Candle Products Messages Manual (KLVHS–KONCT)KN3FC084 TCP/IP PROFILE ALLOCATION FAILED. RC(return_code), ERROR(reason_code), INFO(information_code

Strona 311 - KMQxx001E–KOCJ0046 311

KMQxx001E–KOCJ0046 379KN3FC096 TCPC STATUS COMMAND FAILED ROUTINE=KN3ACTC3 REASON=reason_code RETURN=return_codeExplanation: An error was detected whi

Strona 312

38 Candle Products Messages Manual (KLVHS–KONCT)KLVOP031 REPEATING COMMAND SCHEDULED EVERY nExplanation: The CT/Engine EVERY command was issued.System

Strona 313 - KMQxx001E–KOCJ0046 313

380 Candle Products Messages Manual (KLVHS–KONCT)KN3FC105 OMEGAMON II for VTAM DIAGNOSTIC feature STATUS FAILED ROUTINE=KN3AHFT3 REASON=reason RETURN=

Strona 314

KMQxx001E–KOCJ0046 381KN3FT008 CCCCCC OVERRIDE: nnnExplanation: The CCCCCC environment variable with a value of nnn was read.System Action: Processin

Strona 315 - KMQxx001E–KOCJ0046 315

382 Candle Products Messages Manual (KLVHS–KONCT)User Response: See message KN3FT106.KN3FT106 INCREASE BUFMAX AND/OR REDUCE COLLECT_INTERVALExplanatio

Strona 316

KMQxx001E–KOCJ0046 383KN3FT208 CSVDYNEX ADD FOR (ssssss)(jobname) (xxxx) FAILED RC=yyyy, REASON=zzzzExplanation: Error adding SMF exit ssssss.jobname

Strona 317

384 Candle Products Messages Manual (KLVHS–KONCT)KN3FT216 ADDING SMF EXITSExplanation: Starting to add SMF exits during initialization.System Action:

Strona 318

KMQxx001E–KOCJ0046 385User Response: None. If problem persists, contact Candle Support Services.KN3FT225 RESMGR DELETE ERROR R15=xxxxExplanation: Erro

Strona 319 - KMQxx001E–KOCJ0046 319

386 Candle Products Messages Manual (KLVHS–KONCT)KN3FT502 ERROR: NO EYECATCHER IN CSAExplanation: Resource manager was unable to locate the CSA fo the

Strona 320

KMQxx001E–KOCJ0046 387KN3IR004 TCP|NCP|VTAM MONITOR SUBNODE REGISTERED FOR ORIGINNODE originnodeExplanation: The IRA manager has registered to monitor

Strona 321 - KMQxx001E–KOCJ0046 321

388 Candle Products Messages Manual (KLVHS–KONCT)System Action: The IRA on which the error occurred will not participate in any distributed queries.Us

Strona 322

KMQxx001E–KOCJ0046 389KN3IR909 IRA_Subnode_Deregister error: RC=xx Node=cccccccccccccExplanation: The OMEGAMON XE for Mainframe Networks IRA Registrat

Strona 323 - KMQxx001E–KOCJ0046 323

KLVHS001–KLVSC009 39KLVOP044 SESSION luname NOT FOUNDExplanation: The CT/Engine LOGOFF command was issued, but the session between an active CT/Engine

Strona 324

390 Candle Products Messages Manual (KLVHS–KONCT)System Action: The IRA subnode for which the error occurred will not participate in any distributed q

Strona 325 - KMQxx001E–KOCJ0046 325

KMQxx001E–KOCJ0046 391User Response: Check the TLVLOG for additional messages that may indicate the reason why the registration request failed. If pro

Strona 326

392 Candle Products Messages Manual (KLVHS–KONCT)System Action: The IRA subnode for which the error occurred will not participate in any distributed q

Strona 327 - KMQxx001E–KOCJ0046 327

KMQxx001E–KOCJ0046 393User Response: Log the diagnostic information and contact Candle Support Services.Message Type: Internal error.KN3LC104 MISSING

Strona 328

394 Candle Products Messages Manual (KLVHS–KONCT)User Response: Log the diagnostic information and contact Candle Support Services.Message Type: Inter

Strona 329 - KMQxx001E–KOCJ0046 329

KMQxx001E–KOCJ0046 395User Response: Log the diagnostic information and contact Candle Support Services.Message Type: Internal error.KN3LS103 INVALID

Strona 330

396 Candle Products Messages Manual (KLVHS–KONCT)User Response: Log the diagnostic information and contact Candle Support Services.Message Type: Inter

Strona 331 - HOST TCP/IP host name

KMQxx001E–KOCJ0046 397KN3ND000 NCP STATISTICS COLLECTOR AVAILABLE FOR REQUESTSExplanation: The NCP NPALU collector task can receive requests.System Ac

Strona 332

398 Candle Products Messages Manual (KLVHS–KONCT)KN3ND006 SESSION TERMINATED WITH NPALU=npalu_nameExplanation: The NCP NPALU collector task lost the s

Strona 333 - KMQxx001E–KOCJ0046 333

KMQxx001E–KOCJ0046 399KN3ND012 FAILED TO FIND OWNING RESOURCE owning_resource_name FOR RESOURCE resource_name DURING DYNAMIC DELETEExplanation: The ow

Strona 334

4 Candle Products Messages Manual (KLVHS–KONCT)

Strona 335 - KMQxx001E–KOCJ0046 335

40 Candle Products Messages Manual (KLVHS–KONCT)KLVOP061 SYSTEM OPERATORS: ID(operator) DEV(dev) PEND(pendnum) LIMIT(oplimit) . . . Explanation: The C

Strona 336

400 Candle Products Messages Manual (KLVHS–KONCT)KN3ND017 FAILURE ADDING DYNAMIC RESOURCE(resource_name) TO TOPOLOGY ROUTINE=KN3AHN12 R0=register_valu

Strona 337 - KMQxx001E–KOCJ0046 337

KMQxx001E–KOCJ0046 401KN3ND023 $PAM($PAM_name) FAILED ROUTINE=KN3AGSRC DDNAME=ddname MEMBER=member_name R15=register_value R0=register_value R1=regist

Strona 338

402 Candle Products Messages Manual (KLVHS–KONCT)KN3ND029 NETWORK TOPOLOGY DUPLICATE RESOURCE(resource_name) FOUND IN RRT(RRT_name)Explanation: The sp

Strona 339 - KMQxx001E–KOCJ0046 339

KMQxx001E–KOCJ0046 403KN3ND034 KEYWORD(keyword) ON(macro_name) MACRO WITH LABEL(label_name) IS NOT SPECIFIEDExplanation: This keyword is not explicitl

Strona 340

404 Candle Products Messages Manual (KLVHS–KONCT)KN3ND101 NCP DATA MANAGER TASK IS TERMINATINGExplanation: The NCP data manager task is terminating.Sy

Strona 341 - AUTO nnnn

KMQxx001E–KOCJ0046 405User Response: Depending on the reason code, take recommended action or contact Candle as follows:Message Type: Internal or user

Strona 342

406 Candle Products Messages Manual (KLVHS–KONCT)KN3ND110 API UPDATE TOPOLOGY ERROR KN3AYNCE SNAPExplanation: An internal request by the NCP data mana

Strona 343 - KMQxx001E–KOCJ0046 343

KMQxx001E–KOCJ0046 407KN3ND116 KN3AYNRE RDS SEGMENT ALLOCATION FAILEDExplanation: An internal request by the NCP data manager task has failed.System A

Strona 344

408 Candle Products Messages Manual (KLVHS–KONCT)KN3ND122 API EXTRACT RESOURCE LIST REQUEST FAILED FOR resource_name NPALU=npalu_name RETURN=return_co

Strona 345 - KMQxx001E–KOCJ0046 345

KMQxx001E–KOCJ0046 409KN3ND131 KN3AGNPB SERVICE FUNCTION - FAILED, FUNCTION=function_name, RETURN=return_codeExplanation: A request being processed by

Strona 346

KLVHS001–KLVSC009 41KLVOP102 SESSION STARTED: LU(luname) APPL(appl)Explanation: The LOGON command successfully started a session between application a

Strona 347 - KMQxx001E–KOCJ0046 347

410 Candle Products Messages Manual (KLVHS–KONCT)KN3ND136 BIND FAILURE FOR NPALU=npalu_name SENSE=sense_codeExplanation: The NCP NPALU collector task

Strona 348

KMQxx001E–KOCJ0046 411The contents of the RU appears on the log in character and hexadecimal format after the message text.System Action: The TIC3 dat

Strona 349 - KMQxx001E–KOCJ0046 349

412 Candle Products Messages Manual (KLVHS–KONCT)KN3ND217 SCANNING OF NCP ncp_name STARTEDExplanation: The NCP topology build is being processed.Syste

Strona 350

KMQxx001E–KOCJ0046 413KN3PN003 ACT TERMINATED WITH ERROR — RC(return_code) SC(sense_code)Explanation: ACT (Automatic Collector Task) terminated with e

Strona 351 - KMQxx001E–KOCJ0046 351

414 Candle Products Messages Manual (KLVHS–KONCT)KN3PN008 LOGON ERROR ENCOUNTERED FOR USER userid — FUNCTION function_name) RC(return_code) SENSE(sens

Strona 352

KMQxx001E–KOCJ0046 415KN3PN014 SAM ERROR IN DIALOG calling_dialog — FUNCTION(SAM_function) RC(return_code) LU(lu_name) APPL(applid) USERID(userid) tex

Strona 353 - KMQxx001E–KOCJ0046 353

416 Candle Products Messages Manual (KLVHS–KONCT)KN3PN020 OMEGAMON II FOR VTAM (V500) INITIALIZATION FAILURE - APF AUTHORIZATION FAILEDExplanation: OM

Strona 354

KMQxx001E–KOCJ0046 417KN3PN024 OMEGAMON II FOR VTAM (V500) INITIALIZATION FAILURE - RC(return_code) SC(sense_code)Explanation: OMEGAMON II for VTAM in

Strona 355 - KMQxx001E–KOCJ0046 355

418 Candle Products Messages Manual (KLVHS–KONCT)KN3PN029 OMEGAMON II for DB2 FOR VTAM INTERNAL FUNCTION LEVEL SECURITY ENABLEDExplanation: OMEGAMON I

Strona 356

KMQxx001E–KOCJ0046 419KN3SD002 ERROR PROCESSING AN SDM FUNCTION IN DIALOG calling_dialog — APPL(SDM_application) SESSION(SDM_session_name) FUNCTION(SD

Strona 357 - KMQxx001E–KOCJ0046 357

42 Candle Products Messages Manual (KLVHS–KONCT)KLVOP122 INVALID TRACE ID: argExplanation: The TRACE command contains an invalid parameter arg.System

Strona 358

420 Candle Products Messages Manual (KLVHS–KONCT)KO41034 Monitoring for situation &1 ended.Explanation: A user or program ended a running situatio

Strona 359 - KMQxx001E–KOCJ0046 359

KMQxx001E–KOCJ0046 421User Response: The following lists possible error codes. If a reason code appears that is not on this list, note it and contact

Strona 360

422 Candle Products Messages Manual (KLVHS–KONCT)KO41044 Monitoring for enterprise situation &1 ended.Explanation: A user or program ended a runni

Strona 361 - KMQxx001E–KOCJ0046 361

KMQxx001E–KOCJ0046 423KO46260 Predicate data cannot contain blank field.Explanation: The first parameter for the PDT field cannot contain a blank.User

Strona 362

424 Candle Products Messages Manual (KLVHS–KONCT)User Response: Refer to the appropriate Candle Management Server (CMS) Reference Manual to determine

Strona 363 - KMQxx001E–KOCJ0046 363

KMQxx001E–KOCJ0046 425Another policy contains a CHANGE_POLICY or embedded policy activity that activates this policy.The policy now starts, runs, ends

Strona 364

426 Candle Products Messages Manual (KLVHS–KONCT)KO48081 Ranking group entry &1 in ranking group &2 updated by &3.Explanation: The tanking

Strona 365 - KMQxx001E–KOCJ0046 365

KMQxx001E–KOCJ0046 427KO48090 Policy &1 has deactivated. Restart limit exceeded.Explanation: The policy was defined to restart upon completion and

Strona 366

428 Candle Products Messages Manual (KLVHS–KONCT)KO48099 Policy &3, activity &4 - Changing situation &1 to status &2.Explanation: Poli

Strona 367 - KMQxx001E–KOCJ0046 367

KMQxx001E–KOCJ0046 429KO48143 Policy &3, activity &4 - Escalating user choice from &1 to &2 due to timeout.Explanation: Policy &3,

Strona 368

KLVHS001–KLVSC009 43KLVOP129 TRACE REQUEST REJECTED. TERM(resname) NOT A PHYSICAL TERMINAL.Explanation: The trace for resname of CLASS(TERM) has been

Strona 369 - KMQxx001E–KOCJ0046 369

430 Candle Products Messages Manual (KLVHS–KONCT)KO48155 Execute command: &1 and &2 additional commands of the same form.Severity: 0System Pro

Strona 370

KMQxx001E–KOCJ0046 431KO49021 Situation validation failed. *MIN cannot be used with this attributeExplanation: Attempt to use *MIN with a non-integer

Strona 371 - KMQxx001E–KOCJ0046 371

432 Candle Products Messages Manual (KLVHS–KONCT)KO49030 Situation validation did not complete. *SUM cannot be used with this attribute.Explanation: A

Strona 372

KMQxx001E–KOCJ0046 433KO49038 Situation validation failed; cannot use *SNGPDT predicate with *SIT predicate.Explanation: Attempted to create a situati

Strona 373 - KMQxx001E–KOCJ0046 373

434 Candle Products Messages Manual (KLVHS–KONCT)KO49043 Situation &1 is occurring; &2 events available for status; oldest events discarded.Ex

Strona 374

KMQxx001E–KOCJ0046 435KO4SRV005 Starting Candle Management Server (CMS) network requesters.Severity: 0System Programmer Response:NoKO4SRV006 Network r

Strona 375 - KMQxx001E–KOCJ0046 375

436 Candle Products Messages Manual (KLVHS–KONCT)KO4SRV018 Stopping Candle Management Server (CMS) situation monitor.Severity: 0System Programmer Resp

Strona 376

KMQxx001E–KOCJ0046 437KO4SRV030 Candle Management Server (CMS) shutdown completed.Explanation: CMS was requested to shut down by the END CMS command.S

Strona 377 - KMQxx001E–KOCJ0046 377

438 Candle Products Messages Manual (KLVHS–KONCT)KO4SRV039 Starting Candle Management Server (CMS) data collection event notification.Severity: 0Syste

Strona 378

KMQxx001E–KOCJ0046 439KO4SRV049 Candle Management Server (CMS) started.Severity: 0System Programmer Response:NoKO4SRV050 Startup failed due to errors

Strona 379 - KMQxx001E–KOCJ0046 379

44 Candle Products Messages Manual (KLVHS–KONCT)KLVOP142 INVALID MESSAGE TYPE: typeExplanation: An invalid message type type was specified as one of t

Strona 380

440 Candle Products Messages Manual (KLVHS–KONCT)KO4SRV054 Job &2/&3 submitted.Explanation: Job &2/&3 submitted to job queue &4 in

Strona 381 - KMQxx001E–KOCJ0046 381

KMQxx001E–KOCJ0046 441KO4SRV061 Candle Management Server (CMS) starting Situation &1.Explanation: The CMS received and acknowledged a request to s

Strona 382

442 Candle Products Messages Manual (KLVHS–KONCT)KO4SRV068 Input not supplied for required fields.Explanation: A required parameter was not specified.

Strona 383 - KMQxx001E–KOCJ0046 383

KMQxx001E–KOCJ0046 443KO4SRV074 Not able to update record in configuration file.Explanation: The Candle Management Server (CMS) encountered error cond

Strona 384

444 Candle Products Messages Manual (KLVHS–KONCT)KO4SRV080 Value &3 not valid for parameter &2.Explanation: A required value was not entered f

Strona 385 - KMQxx001E–KOCJ0046 385

KMQxx001E–KOCJ0046 445KO4SRV089 Specify *SNA Directory Server.Explanation: An *SNA directory server must be specified when no Candle Management Server

Strona 386

446 Candle Products Messages Manual (KLVHS–KONCT)KO4SRV096 Multiple predicates required with PDTREL value *AND or *OR.Explanation: You entered *AND or

Strona 387 - KMQxx001E–KOCJ0046 387

KMQxx001E–KOCJ0046 447User Response: Enter a correct value for this attribute. Refer to the appropriate Candle Management Server (CMS) Reference Manua

Strona 388

448 Candle Products Messages Manual (KLVHS–KONCT)System Programmer Response:NoKOCJO001 INITIALIZE COMPLETED NORMALLY.Explanation: This facility has in

Strona 389 - KMQxx001E–KOCJ0046 389

KMQxx001E–KOCJ0046 449KOCJO008 UNABLE TO DETERMINE START TYPE.Explanation: The facility was unable to determine how it was invoked. This can occur if

Strona 390

KLVHS001–KLVSC009 45KLVOP165 CLOSE COMPLETE: APPLID(applid)Explanation: The CLOSE command was issued against applid and completed successfully.System

Strona 391 - KMQxx001E–KOCJ0046 391

450 Candle Products Messages Manual (KLVHS–KONCT)KOCJO014 SUSPEND TRANSACTION INACTIVE.Explanation: An attempt to suspend the facility was made and th

Strona 392

KMQxx001E–KOCJ0046 451KOCJO020 GETMAIN FAILURE.Explanation: An error was detected when attempting to obtain storage for use as a buffer.System Action:

Strona 393 - KMQxx001E–KOCJ0046 393

452 Candle Products Messages Manual (KLVHS–KONCT)User Response: Use AUXTRACE or CEDF to determine the cause of the unexpected return code. If you dete

Strona 394

KMQxx001E–KOCJ0046 453KOCJO032 UNKNOWN FUNCTION IN PROCESS.Explanation: A request was issued and an unknown function was in progress.System Action: Th

Strona 395 - KMQxx001E–KOCJ0046 395

454 Candle Products Messages Manual (KLVHS–KONCT)KOCJO038 ERROR RECEIVED DURING FREEMAIN PROCESSING.Explanation: An error was detected when attempting

Strona 396

KMQxx001E–KOCJ0046 455KOCJO044 NETNAME NOT PRESENT IN DICTIONARY.Explanation: The global user exit has determined that the network name field is not p

Strona 397 - KMQxx001E–KOCJ0046 397

456 Candle Products Messages Manual (KLVHS–KONCT)

Strona 398

KOGCM001–KONCT303 457KOGCM001–KONCT303KOGCM001 FUNCTION=PSMREAD, RC=rc {LU(luname) SESSID(sessid)}Explanation: A problem occurred while reading a comm

Strona 399 - KMQxx001E–KOCJ0046 399

458 Candle Products Messages Manual (KLVHS–KONCT)KOGCM005 LU(luname) OG/MVS Command input: commandExplanation: The specified command input was receive

Strona 400

KOGCM001–KONCT303 459This appears while waiting for VTAM to initially update the status, if errors are found in the APPSTAT request, or if the status

Strona 401 - KMQxx001E–KOCJ0046 401

46 Candle Products Messages Manual (KLVHS–KONCT)KLVOP191 REPLY FROM operator: COMMAND(command)Explanation: Operator operator issued command command. T

Strona 402

460 Candle Products Messages Manual (KLVHS–KONCT)KOGEC003 LU(luname) \K keynameExplanation: A \K command to transmit an aid key to a started applicati

Strona 403 - KMQxx001E–KOCJ0046 403

KOGCM001–KONCT303 461KOGEC008 KABSEVAL INVOKED NAME=name VALUE=valueExplanation: The dialog KABSEVAL has been called to evaluate a named variable.Syst

Strona 404

462 Candle Products Messages Manual (KLVHS–KONCT)KOGEC013 \SET ABORT PSMREAD RC=rcExplanation: The PSMREAD function used to read parameters passed for

Strona 405

KOGCM001–KONCT303 463KOGEC018 Expected Environment Command prefix character is prefixcharExplanation: The character given by prefixchar has been estab

Strona 406

464 Candle Products Messages Manual (KLVHS–KONCT)KOGEV004 VSSENTRY FAILED WITH RC=nnExplanation: Initialization of POVI’s virtual session services fai

Strona 407 - KMQxx001E–KOCJ0046 407

KOGCM001–KONCT303 465KOGLM003 LU(luname) WILL USE LOGMODE=logmode FOR ITS VIRTUAL SESSIONSExplanation: The specified LU will use the specified logmode

Strona 408

466 Candle Products Messages Manual (KLVHS–KONCT)User Response: Examine the POVI log for more detailed messages describing the problem.Message Type: L

Strona 409 - KMQxx001E–KOCJ0046 409

KOGCM001–KONCT303 467KOGOP005 VDEFINE ERROR FOR SESSID sessid, RC=nnExplanation: An internal logic error caused the current APPLDEF command to fail.Sy

Strona 410

468 Candle Products Messages Manual (KLVHS–KONCT)System Action: Further communication with the product may not be possible.User Response: Examine the

Strona 411 - KMQxx001E–KOCJ0046 411

KOGCM001–KONCT303 469System Action: By default, both physical and virtual sessions are terminated. If POVI has been configured using the "return

Strona 412

KLVHS001–KLVSC009 47KLVOP194 RESOURCE NAME IS REQUIREDExplanation: The AUTOPURG command requires a resource name as part of the AUTOPURGE criteria.Sys

Strona 413 - KMQxx001E–KOCJ0046 413

470 Candle Products Messages Manual (KLVHS–KONCT)Message Type: LOG.KOGRU018 ILLOGICAL KEY:xxxx FROM LU "luname"Explanation: Someone has logg

Strona 414

KOGCM001–KONCT303 471User Response: Examine the POVI log for more detailed messages describing the problem.Message Type: LOG.KOGTB001 FUNCTION=TBCREAT

Strona 415 - KMQxx001E–KOCJ0046 415

472 Candle Products Messages Manual (KLVHS–KONCT)User Response: Report the error message along with a problem description to Candle Customer Support.M

Strona 416

KOGCM001–KONCT303 473KOGUT005 Importing|Exporting scriptname from|to pdsname.Explanation: The attempted import or export is being processed.System Act

Strona 417 - KMQxx001E–KOCJ0046 417

474 Candle Products Messages Manual (KLVHS–KONCT)KOGUT012 Records truncated. RECFM not V|VB or LRECL<512.Explanation: A write of records having a l

Strona 418

KOGCM001–KONCT303 475KOGVL05S UNABLE TO DETERMINE SLU APPLIDExplanation: An attempt to determine the SLU APPLID of the VU Client failed.System Action:

Strona 419

476 Candle Products Messages Manual (KLVHS–KONCT)KOGVL10I INBOUND LU0 PACKET (STATUS=status):Explanation: This message precedes message KOGVL15I and i

Strona 420

KOGCM001–KONCT303 477KOGVL14I OUTBOUND LU0 PACKET:Explanation: This message precedes message KOGVL15I and is used to diagnose VTAM session problems.Sy

Strona 421

478 Candle Products Messages Manual (KLVHS–KONCT)KOGVL21I CLEANUP FOR SESSION/PATH VUSPLR=addressExplanation: Cleanup and termination of a session/pat

Strona 422

KOGCM001–KONCT303 479KOGVL25E INVALID REQUEST=reqtype FROM SLU APPLID=applid MATCHNO=prcnoExplanation: An invalid request type for a VU request was sp

Strona 423 - KMQxx001E–KOCJ0046 423

48 Candle Products Messages Manual (KLVHS–KONCT)KLVOP205 INCONSISTENT SPECIFICATION: NETNAME(netname) ACBNAME(acbname) THROUGH(thru)Explanation: An in

Strona 424

480 Candle Products Messages Manual (KLVHS–KONCT)KOGVL30E UNABLE TO TERMINATE lrtype STATUS=statusExplanation: An attempt to terminate and cleanup a l

Strona 425 - KMQxx001E–KOCJ0046 425

KOGCM001–KONCT303 481KOGVL33I pdutype REQUEST CONTINUED. LRN=lrn @address SEQNO=seqnoExplanation: An multi-packet Protocol Data Unit was successfully

Strona 426

482 Candle Products Messages Manual (KLVHS–KONCT)KOGVL38E INVALID NO. SUBSTITUTE VALUES=novals EXPECTED=enovalsExplanation: The number of values recei

Strona 427 - KMQxx001E–KOCJ0046 427

KOGCM001–KONCT303 483KOGVS001 LU(luname) STARTING VIRTUAL SESSION FOR sessid, APPL=appl, POOL=pool, LOGMODE=logmodeExplanation: The session given by s

Strona 428

484 Candle Products Messages Manual (KLVHS–KONCT)KOGVS01E INVALID VALUE FOR PLU APPLID=applidExplanation: The VTAM Primary Logical Unit Application ID

Strona 429 - KMQxx001E–KOCJ0046 429

KOGCM001–KONCT303 485KOGVS05E VU SERVER IPC QUEUE CREATE ERROR=statusExplanation: An attempt to create the interprocess communication queue for the VU

Strona 430

486 Candle Products Messages Manual (KLVHS–KONCT)KOGVS13I VUPL=address DISPATCHED TO THREAD=threadIDExplanation: A VU service request has been success

Strona 431 - KMQxx001E–KOCJ0046 431

KOGCM001–KONCT303 487KOGVT10E UNABLE TO LOCATE PARAMETERS LRN=lrnExplanation: An attempt to locate a VU service parameter list resource required to ex

Strona 432

488 Candle Products Messages Manual (KLVHS–KONCT)KOGVT17W LOCATE SERVER FAILED STATUS=status REASON=reasonExplanation: The CT Data Server name cannot

Strona 433 - KMQxx001E–KOCJ0046 433

KOGCM001–KONCT303 489KOGVT22E sqlroutine FAILED. STATUS=statusExplanation: An internal service routine (SQL1 API function) was called and returned a n

Strona 434

KLVHS001–KLVSC009 49KLVOP210 NOCAPPL SPECIFIED IN A NON DEDICATE POOL IGNOREDExplanation: The parameter NOCAPPL can be specified only on a DEDICATE po

Strona 435 - KMQxx001E–KOCJ0046 435

490 Candle Products Messages Manual (KLVHS–KONCT)KOGVT26I COMPILING SQL=sqlExplanation: This message is issued prior to compilation of a query, insert

Strona 436

KOGCM001–KONCT303 491KOGVT31I SUBSTITUTING novals VALUES INTO REQUEST LRN=lrnExplanation: This message is issued prior to executing a substitute reque

Strona 437 - KMQxx001E–KOCJ0046 437

492 Candle Products Messages Manual (KLVHS–KONCT)KOGVT34I SUBSTITUTING parmname=value TYPE=type LENGTH=lengthExplanation: This message is issued prior

Strona 438

KOGCM001–KONCT303 493KOGVT38E FETCH ATTEMPTED BEYOND END OF DATA REQUEST LRN=lrnExplanation: An attempt to fetch rows beyond the last row of a query w

Strona 439

494 Candle Products Messages Manual (KLVHS–KONCT)KONAF003 BACKGROUND ETE COLLECTOR TERMINATED WITH ERROR — MODULE(error_module) RC(return_code) SC(sen

Strona 440

KOGCM001–KONCT303 495KONAF010 CRB ALLOCATION FAILED DURING [TRACE CLEANUP] | [TRACE DELETE] | [TRACE DISPLAY] | [TRACE INSTALL] | [TRACE REMOVAL] | [T

Strona 441 - KMQxx001E–KOCJ0046 441

496 Candle Products Messages Manual (KLVHS–KONCT)KONAF021 UNABLE TO OBTAIN LOCK — TYPE(lock_name) MODULE(error_module)Explanation: While attempting to

Strona 442

KOGCM001–KONCT303 497KONAF042 UNABLE TO FREEMAIN USERWORK DURING SESSION TERMINATION — MODULE(error_module) RC(return_code)Explanation: FREEMAIN of a

Strona 443 - KMQxx001E–KOCJ0046 443

498 Candle Products Messages Manual (KLVHS–KONCT)KONAF046 ERROR ENCOUNTERED REMOVING TRACE FACILITY DURING SESSION TERMINATION — MODULE(error_module)

Strona 444

KOGCM001–KONCT303 499KONAF051 CLUSTER INITIAL LOAD FAILED FOR DDNAME(ddname) — MODULE(error_module) SERVICE(cccc) RC(nn)Explanation: An error occurred

Strona 445 - KMQxx001E–KOCJ0046 445

KLVHS001–KLVSC009 5KLVHS001–KLVSC009KLVHS001 HANDLE SERVICES MANAGER INITIALIZATION COMPLETEExplanation: The Handle Services initialization module has

Strona 446

50 Candle Products Messages Manual (KLVHS–KONCT)KLVOP302 VIEWLOG CLUSTER NOT AVAILABLEExplanation: The VIEWLOG cluster specified in the VIEWLOG comman

Strona 447 - KMQxx001E–KOCJ0046 447

500 Candle Products Messages Manual (KLVHS–KONCT)KONAF056 ALLOCATING DATASET dsnameExplanation: VSAM cluster dsname is being allocated for OMEGAMON II

Strona 448

KOGCM001–KONCT303 501KONAF060 VSAM LOGGING DISABLED — MODULE(error_module) REASON (cccccccc)Explanation: VSAM logging is disabled and the reason for i

Strona 449 - KMQxx001E–KOCJ0046 449

502 Candle Products Messages Manual (KLVHS–KONCT)KONAF110 dialog_function - UNABLE TO OBTAIN PASSED PARAMETER(parameter_name)Explanation: The dialog f

Strona 450

KOGCM001–KONCT303 503KONAF115 KONAFNM1 - UNABLE TO LOCATE SITE MONITOR TABLE: tablename.Explanation: The dialog function was unable to obtain the hand

Strona 451 - KMQxx001E–KOCJ0046 451

504 Candle Products Messages Manual (KLVHS–KONCT)KONAF120 NDM FUNCTIONS INITIALIZATION FAILED REASON(reason_code)Explanation: The automatic collection

Strona 452

KOGCM001–KONCT303 505KONAF125 NCP DATA UPDATE ERRORS DETECTED RC(return_code) SC(sense code)Explanation: NCP data manager (NDM) was unable to refresh

Strona 453 - KMQxx001E–KOCJ0046 453

506 Candle Products Messages Manual (KLVHS–KONCT)KONAF130 START REQUEST RESOURCE(resource_name) NPALU(npalu_name) GENDATE(generation_date) GENTIME(gen

Strona 454

KOGCM001–KONCT303 507KONAF134 NCP TOPOLOGY NOT CREATED. WILL RETRY NEXT ACT CYCLE INTERVALExplanation: The NCP resources have not been received from t

Strona 455 - KMQxx001E–KOCJ0046 455

508 Candle Products Messages Manual (KLVHS–KONCT)KONAF138 KONAXNPB GET_HASH FUNCTION FAILED RC(return_code) MODULE(module_name)Explanation: An error w

Strona 456

KOGCM001–KONCT303 509KNOAF143 NCP VSAM LOGGING MODULE KONAFNVW LOAD FAILED. NCP STATISTICS DATA NOT AVAILABLE.Explanation: The automatic collection ta

Strona 457 - KOGCM001–KONCT303

KLVHS001–KLVSC009 51KLVOP402 UNABLE TO ALLOCATE JES SPOOL FILE: REASON(rsn)Explanation: The BATCH command did not complete because CT/Engine was unabl

Strona 458

510 Candle Products Messages Manual (KLVHS–KONCT)KONAF148 module_name LOWER LEVEL MONITORED RESOURCES EXIST FOR resource_nameExplanation: A request to

Strona 459

KOGCM001–KONCT303 511KONAF153 ACT NPB CHECK FOR RESOURCE(ncp_resource_name) NPALU(npalu_name) FAILED RC(return_code)Explanation: The Automatic Collect

Strona 460

512 Candle Products Messages Manual (KLVHS–KONCT)KONAF157 TOPOLOGY UPATE FUNCTIONS MODULE KONAFNUT LOAD FAILED. NCP STATISTICS DATA NOT AVAILABLE.Expl

Strona 461 - KOGCM001–KONCT303 461

KOGCM001–KONCT303 513KONCT000 TCP/IP STATISTICS COLLECTOR INITIALIZATION COMPLETEExplanation: The TCP/IP collector successfully initialized.System Act

Strona 462

514 Candle Products Messages Manual (KLVHS–KONCT)KONCT009 {TCP/IP COLLECTOR | MIB BROWSER} MEMORY ALLOCATION FAILEDExplanation: A memory allocation fa

Strona 463 - KOGCM001–KONCT303 463

KOGCM001–KONCT303 515KONCT015 SNMP MANAGER ATTACH FAILED: RC(return_code)Explanation: The attach of the SNMP manager task failed.System Action: The TC

Strona 464 - EXITED PROGRAMMERLESS OVI

516 Candle Products Messages Manual (KLVHS–KONCT)KONCT102 {TCP/IP SERVICE THREAD | MIB BROWSER | XMCS} ABENDED, CODE=abend_code, PSW=program_status_wo

Strona 465 - KOGCM001–KONCT303 465

KOGCM001–KONCT303 517KONCT112 $GMEM FAILED FOR COMMAND OUTPUT RECORDExplanation: A memory allocation failed in the TCP/IP service task.System Action:

Strona 466

518 Candle Products Messages Manual (KLVHS–KONCT)KONCT125 NAME=name STATUS=status HOST=host IPADDR=xxx.xxx.xxx.xxxExplanation: One KONCT125 message pe

Strona 467 - KOGCM001–KONCT303 467

KOGCM001–KONCT303 519KONCT202 KONCT202 module - STORAGE ALLOCATION FAILURE SIZE = bytesExplanation: The specified module was unable to allocate the sp

Strona 468

52 Candle Products Messages Manual (KLVHS–KONCT)KLVOP502 CT/Engine JOBSTEP NOT AUTHORIZED, COMMAND REJECTEDExplanation: CT/Engine is not running from

Strona 469 - KOGCM001–KONCT303 469

520 Candle Products Messages Manual (KLVHS–KONCT)KONCT208 KONCT208 kONAITXB - EZASMI GETHOSTNAME FAILUREExplanation: Module KONAITXB could not perform

Strona 470

KOGCM001–KONCT303 521KONCT303 KONCT303 KONAITDD - INVALID ELEMENT PARAMETER parmExplanation: Module KONAITDD received a request with the specified ele

Strona 471 - KOGCM001–KONCT303 471

522 Candle Products Messages Manual (KLVHS–KONCT)

Strona 472

KLVHS001–KLVSC009 53KLVOP555 FORWARD TO appldest FROM appl1 STOPPEDExplanation: The forwarding of application appl1 was successfully stopped by the FO

Strona 473 - KOGCM001–KONCT303 473

54 Candle Products Messages Manual (KLVHS–KONCT)KLVOP655 LOGON DIALOG UNAVAILABLE: DIALOG(dialog) LANGUAGE(language)Explanation: A DIALOG command was

Strona 474

KLVHS001–KLVSC009 55KLVOP803 UNABLE TO OPEN DATASET: DSNAME(dsname)Explanation: The PRINT command completed unsuccessfully because dsname could not be

Strona 475 - KOGCM001–KONCT303 475

56 Candle Products Messages Manual (KLVHS–KONCT)KLVOP853 UNABLE TO OPEN NODE ACB: APPLID(appl) REASON (rc)Explanation: The NODE command failed because

Strona 476

KLVHS001–KLVSC009 57KLVOP901 NAM INACTIVEExplanation: The NAM command failed because the NAM facility is inactive. Either no parameters were specified

Strona 477 - KOGCM001–KONCT303 477

58 Candle Products Messages Manual (KLVHS–KONCT)KLVOP908 DUPLICATE DECLARATION: varnameExplanation: The NAM DECLARE command completed unsuccessfully b

Strona 478

KLVHS001–KLVSC009 59KLVOP915 VARIABLE name LENGTH lenExplanation: The NAM VLIST command was issued, and the declared variables with the corresponding

Strona 479 - KOGCM001–KONCT303 479

6 Candle Products Messages Manual (KLVHS–KONCT)KLVHS011 MAXPOOLS(pools) USING(rpools), MAXHANDLES(handles) USING(rhandles)Explanation: The specified M

Strona 480

60 Candle Products Messages Manual (KLVHS–KONCT)KLVOP922 VARIABLE EXPRESSION TOO LONG FOR varname: exprExplanation: The NAM SET command was issued, bu

Strona 481 - KOGCM001–KONCT303 481

KLVHS001–KLVSC009 61KLVOP930 cpname [,SAF(SUBSYS=sysid,REQUESTOR=rqid)] [,RACF] [,DB] [,EXIT] [,NOTIFY] [,NONAF] [DATABASE=dsname]Explanation: The NAM

Strona 482

62 Candle Products Messages Manual (KLVHS–KONCT)KLVOP963 COMMAND ERROR, RTM INTERFACE MAY BE SET “ON” OR “OFF”Explanation: ON or OFF was not specified

Strona 483 - KOGCM001–KONCT303 483

KLVHS001–KLVSC009 63KLVOP968 RTM NPM INTERFACE ENABLED - USEREXIT: exit-nameExplanation: An RTM ON command for the NPM response time monitor was succe

Strona 484

64 Candle Products Messages Manual (KLVHS–KONCT)KLVOP975 COMMAND ERROR, INTERNAL: value IS INVALIDExplanation: A GTF command with an invalid value for

Strona 485 - KOGCM001–KONCT303 485

KLVHS001–KLVSC009 65KLVPA004 LIBRARY ddname UNUSABLE, REFRESH FAILEDExplanation: A physical error occurred while reading the library referenced by ddn

Strona 486

66 Candle Products Messages Manual (KLVHS–KONCT)KLVPM001 PSM NOT AVAILABLE: DIALOG(dlg) LU(lu) APPL(appl)Explanation: A dialog attempted to execute a

Strona 487 - KOGCM001–KONCT303 487

KLVHS001–KLVSC009 67KLVPM011 TERMINAL luname LOGGED OFF - ERPCOUNT EXCEEDEDExplanation: A terminal, "luname", has caused more simultaneous e

Strona 488

68 Candle Products Messages Manual (KLVHS–KONCT)Table 1. Description of reason codes for KLVPM021Reason Code DescriptionSystem ActionUser Response0601

Strona 489 - KOGCM001–KONCT303 489

KLVHS001–KLVSC009 69System Action: One of the following:Action 1. Error recovery displays the TERMINAL INPUT ERROR message on the terminal. The input

Strona 490

KLVHS001–KLVSC009 7KLVHS205 INVALID RELEASE HANDLE REQUESTExplanation: The handle use count was already zero during the processing of a Handle Service

Strona 491 - KOGCM001–KONCT303 491

70 Candle Products Messages Manual (KLVHS–KONCT)KLVPM052 parametersExplanation: As the parameters in module KLVINPSM are read, a log audit trail is cr

Strona 492

KLVHS001–KLVSC009 71KLVRE004 UNABLE TO REFRESH DIALOG dlgname LANGUAGE(language)Explanation: An error occurred while trying to refresh the DIALOG dlgn

Strona 493 - KOGCM001–KONCT303 493

72 Candle Products Messages Manual (KLVHS–KONCT)KLVRE009 SENSE CODE TABLE REFRESH FROM "dsname(member)" resulttextExplanation: A REFRESH SEN

Strona 494

KLVHS001–KLVSC009 73KLVRM004 LOGICAL RESOURCE EXIT STACK INTEGRITY ERRORExplanation: The CT/Engine Resource Manager detected inconsistent data while p

Strona 495 - KOGCM001–KONCT303 495

74 Candle Products Messages Manual (KLVHS–KONCT)KLVRT011 NPM MODULE FNMNSI REQUIRES APF AUTHORIZATIONExplanation: RTM support for NPM has been selecte

Strona 496

KLVHS001–KLVSC009 75KLVRT020 RTM NPM SEND REQUEST FAILED: LU=lu-name APPL=applname EVENT=X’xx’Explanation: A non-zero return code was returned from th

Strona 497 - KOGCM001–KONCT303 497

76 Candle Products Messages Manual (KLVHS–KONCT)KLVRT030 $STG ERRORExplanation: CT/Engine was unable to allocate storage for the ETE or NetSpy mapping

Strona 498

KLVHS001–KLVSC009 77KLVSC004 OPERAND TOO LONG: environmental_information operandExplanation: CT/Engine was parsing a line and encountered a keyword or

Strona 499 - KOGCM001–KONCT303 499

78 Candle Products Messages Manual (KLVHS–KONCT)System Action: The action being performed terminates.User Response: The environmental portion of the m

Strona 500

KLVSD001–KLXOP005 79KLVSD001–KLXOP005KLVSD001 PRIMARY MAIN STORAGE INFORMATION:Explanation: The STORAGE command was issued and this message identifies

Strona 501

8 Candle Products Messages Manual (KLVHS–KONCT)KLVHS817 TOTAL EXPANSIONS = totalexpansionsExplanation: The total number of times the Handle Services M

Strona 502

80 Candle Products Messages Manual (KLVHS–KONCT)System Action: None.User Response: None.Message Type: REPLY.KLVSD005 LIMIT(stolim) SLOPE(sl) SIZES(ran

Strona 503 - KOGCM001–KONCT303 503

KLVSD001–KLXOP005 81KLVSD007 pp% IS IN USE; tt% ALLOWED [- THRESHOLD EXCEEDED]Explanation: This message displays the amount of storage in use for prim

Strona 504

82 Candle Products Messages Manual (KLVHS–KONCT)KLVSD021 TMS(num) PREFIX(pfx) CUSHION(cshn)Explanation: This message appears in response to the CT/Eng

Strona 505 - KOGCM001–KONCT303 505

KLVSD001–KLXOP005 83KLVSD033 BUFFERS INUSE(inuse) MAX(max) GETS(gets) FREES(frees)Explanation: This message provides additional information about a bu

Strona 506

84 Candle Products Messages Manual (KLVHS–KONCT)System Action: None.User Response: None.Message Type: REPLY.KLVSD039 END OF BUFFER POOL INFORMATIONExp

Strona 507 - KOGCM001–KONCT303 507

KLVSD001–KLXOP005 85KLVSD104 NAME(...) SIZE(length) TOTAL(count)Explanation: This message displays information about the content of carved, allocated

Strona 508

86 Candle Products Messages Manual (KLVHS–KONCT)KLVSD107 STORAGE MAP FOR areadesc STORAGEExplanation: This message displays the specific areas of stor

Strona 509 - KOGCM001–KONCT303 509

KLVSD001–KLXOP005 87KLVSE054 SYNTAX ERROR CONFLICTING PARAMETERS FOR SENSE ACTION SETTING ‘statement’, STATEMENT# nnnExplanation: The sense code state

Strona 510

88 Candle Products Messages Manual (KLVHS–KONCT)KLVSE059 SENSE TABLE TOO LARGE, IGNOREDExplanation: The sense code table exceeds 2G bytes and cannot b

Strona 511

KLVSD001–KLXOP005 89KLVSE064 parametersExplanation: As the parameters in module KLVINSNS are read, a log audit trail is created.System Action: None.Us

Strona 512

KLVHS001–KLVSC009 9KLVHS830 INVALID OWNERID SPECIFIED ON QUERYHSM COMMAND - owneridExplanation: The specified ownerid is not a valid logical resource

Strona 513 - KOGCM001–KONCT303 513

90 Candle Products Messages Manual (KLVHS–KONCT)KLVSI006 KLVINSTG RKANPAR PARAMETERS:Explanation: Module KLVINSTG logs its start-up parameters as they

Strona 514

KLVSD001–KLXOP005 91KLVSI022 INVALID STORAGE CLASS ON TERMINATE REQUESTExplanation: An internal processing error occurred during storage isolation pro

Strona 515 - KOGCM001–KONCT303 515

92 Candle Products Messages Manual (KLVHS–KONCT)KLVSI041 ZERO ADDRESS ON FREE REQUESTExplanation: A request to free a storage block at address zero wa

Strona 516

KLVSD001–KLXOP005 93KLVSP001 $SPS INVOCATION OR INTERNAL ERRORExplanation: A CT/Engine processing routine detected an invalid request.System Action: T

Strona 517 - KOGCM001–KONCT303 517

94 Candle Products Messages Manual (KLVHS–KONCT)KLVSS002 SUBSYSTEM name INITIALIZED: SSCVT(addr)Explanation: The CT/Engine subsystem interface name wi

Strona 518

KLVSD001–KLXOP005 95KLVST001 CANDLE ENGINE INITIALIZATION ERROR(S), ABEND U0012Explanation: One or more errors were detected during CT/Engine start-up

Strona 519 - KOGCM001–KONCT303 519

96 Candle Products Messages Manual (KLVHS–KONCT)KLVST007 BLDVRP FAILED FOR VSAM LSR BUFFER POOL, RC=rcExplanation: A BLDVRP macro was issued to alloca

Strona 520

KLVSD001–KLXOP005 97KLVST012 EXTENDED MAIN STORAGE UNAVAILABLEExplanation: A variable length GETMAIN could not be satisfied. The MINIMUM(nnn,X) start-

Strona 521 - KOGCM001–KONCT303 521

98 Candle Products Messages Manual (KLVHS–KONCT)KLVST018 UNABLE TO OPEN RKLVLOG DATASET Explanation:System Action: CT/Engine terminates.User Response:

Strona 522

KLVSD001–KLXOP005 99KLVST024 FREE STORAGE LIST UNAVAILABLEExplanation: CT/Engine was unable to allocate the free storage list because the MINIMUM para

Komentarze do niniejszej Instrukcji

Brak uwag